MN-DMD2050E Revision 2 Comtech EF Data is an AS9100 Rev B / ISO9001:2000 Registered Company DMD-2050E Universal Satellite Modem Installa

Page 2

BLANK PAGE

Page 3

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–58 Table 3-4. Reed-Solomon Codes Type of Service Data Rate (Kbps)

Page 4

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–59 rate through the modem. The overhead channel is recovered at t

Page 5

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–60 Kbps Standard IBS Baud Rate Example Kbps Enhanced Mode Baud R

Page 6

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–61 The ratio of the Through Terrestrial Data Channel Rate to the

Page 7

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–62 The user can connect whichever systems on the earth stations th

Page 8

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–63 The number of user data slots and control words per frame is se

Page 9

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–64 3.19.2 Aggregate Data Rate The aggregate data rate equals the

Page 10 - BLANK PAGE

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–65 3.19.3 Overhead Rate Comparison The SCC Overhead Ratio varies

Page 11 - Table of Contents

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–66 3.19.4 Actual Overhead Rate Calculation The following is the a

Page 12

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–67 3.20 SCC OVERHEAD CHANNEL SETUP 1. Set the Framing Mode (loca

Page 13

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E iii Table of Contents PREFACE ...

Page 14

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–68 9. The physical connection to the DMD2050E for the overhead ch

Page 15 - vii

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–69 3.21 Locating the DMD2050E ID Code Operational Procedure Uniqu

Page 16 - viii

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–70 BLANK PAGE

Page 17

MN-DMD2050E Revision 2 4–1 Chapter 4. User Interfaces 4.1 User Interfaces The DMD2050E has three interfaces available for typical operations: •

Page 18

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–2 Table 4-1. Front Panel Functions Area Function VFD Shows operating

Page 19

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–3 Parameter Type 0 – 9     Clear &  Clear &  IP Address

Page 20 - xii

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–4 4.3 Parameter Setup 4.3.1 Select a Parameter Use the arrow keys to

Page 21 - xiii

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–5 4.4.1 MODULATOR Main Menu and Parameters 4.4.1.1 NETWORK SPEC (men

Page 22 - xiv

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–6 4.4.1.2 STRAP CODE The STRAP CODE is another means for quickly sett

Page 23 - Figures

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–7 DATA MENU Trellis (8PSK) {2/3} TPC (BPSK) {5/16, 21/44} ≤ 20Mbp

Page 24 - xvi

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E iv CHAPTER 2. INSTALLATION ...

Page 25 - PREFACE

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–8 DATA MENU TERR FRAMING {NONE, 188, 204} DVB Only DATA POLARITY {I

Page 26 - Grounding

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–9 4.4.1.5 REED-SOLOMON (menu) IMPORTANT When Reed-Solomon is select

Page 27 - Low Voltage Directive (LVD)

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–10 4.4.1.7 LOCAL AUPC (menu) NOTE When modems are configured for Rad

Page 28 - CE Mark

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–11 LOCAL AUPC MENU MINIMUM TX POWER {0 to -45 dB} Set the minimum Tran

Page 29 - Preface MN-DMD2050E

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–12 LOCAL AUPC MENU TARGET Eb/No {4.0 to 16 dB} Set the desired Eb/No f

Page 30

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–13 4.4.1.8 REMOTE AUPC (menu) NOTE Remote AUPC Menus are available o

Page 31 - Chapter 1. Introduction

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–14 8PSK 2/3 {NOT SELECTED, SELECTED} Used to select the mod/code rate

Page 32 - 1.2.1 Features

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–15 Closed Net All possible combinations are allowed. NOTE: DVB settin

Page 33 - 1.2.3 Bandwidth Compression

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–16 IF MENU INPUT THRESHOLD (dBm) {-30 to –90} Sets the minimum carrie

Page 34 - 1.2.7 Physical Description

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–17 DATA MENU SCRAMBLER SEL {NONE, V.35-IESS, V.35 CITT, V.35 EF, IBS w

Page 35

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E v 3.5.3.3 SCT: Serial Clock Transmit ...

Page 36

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–18 4.4.2.6 CNC (menu) IMPORTANT When the Carrier-in-Carrier® option

Page 37 - Chapter 2. Installation

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–19 4.4.3 INTERFACE Main Menu and Parameters 4.4.3.1 TX SETUP (menu)

Page 38 - 2.2 Installation Safety

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–20 IMPORTANT When Ethernet Interface is selected or EBEM Network spe

Page 39 - 2.3.4 Electrical Power

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–21 4.4.3.1.1 DROP & INSERT (menu) DROP & INSERT MENU DROP MOD

Page 40 - 2.3.5 Cables

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–22 4.4.3.2 RX SETUP (menu) RX SETUP MENU CIRCUIT ID Enter the Rx Ci

Page 41 - 2.5.1 Initial Start Up

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–23 4.4.3.2.1 DROP & INSERT (menu) INSERT MODE {NONE, T1-D4, T1-ES

Page 42

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–24 4.4.3.3 GENERAL (menu) GENERAL MENU EXT FREQ (MHz) {Variable Throu

Page 43 - 3.1 DMD2050E Hardware

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–25 MONITOR MENU CORRECTED BER The CBER display shows an estimated corr

Page 44

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–26 NOTE Port status indicators are: Down: The link is down. Unreso

Page 45

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–27 4.4.4.2 VOLTAGES (menu) VOLTAGES MENU TEMPERATURE Displays interna

Page 46

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E vi 3.11.12.4 Estimating PSD Ratio from Satmaster ...

Page 47 - 3.2.2 Baseband Processing

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–28 4.4.5 ALARMS Main Menu and Parameters Alarm details are described

Page 48

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–29 4.4.6.3 TERMINAL (menu) TYPE {VT-100, WYSE50, VIEWPOINT} Select t

Page 49

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–30 TCP/IP MENU BOOTp SERVER {128 – 257, default is 206} Only used if

Page 50 - 3.2.6 Terminal Port

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–31 4.4.6.6 SNMP (menu) A description of OID organization is provided

Page 51 - 3.2.9 Modem Monitor Status

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–32 4.4.6.7 FTP (menu) PORT {XXXX} Select the desired port number.

Page 52 - 3.3 Internal Clock

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–33 4.4.6.9 TRANSEC (menu) TRANSEC MENU IP ADDR MASK {XXX.XXX.XXX.XXX}

Page 53

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–34 4.4.6.10.1 MAIN BOARD (menu) NOTE Only the applicable VCO adjustm

Page 54

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–35 CNC BOARD (menu) Indicates the part number for the CNC Board. DEBU

Page 55 - 3.5.1 Clock Selection

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–36 4.4.7 TEST Main Menu and Parameters TEST MENU TX TEST PATTERN {NON

Page 56 - 3.5.2 TX Clock Options

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–37 TEST MENU IQ SAMPLING {ENABLE/DISABLE} Enables the I & Q patte

Page 57

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E vii 4.4 Front Panel Main Menus ...

Page 58 - 3.5.3.1 RX SAT Clock

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–38 4.5 Terminal Mode Control The Terminal Mode Control lets you use a

Page 59 - Frequency 1 MHz to 20 MHz

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–39 For numerical input, use the number keys to input the data. Press E

Page 60 - 3.6.3 HSSI Interface

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–40 BLANK PAGE

Page 61

MN-DMD2050E Revision 2 5–1 Chapter 5. External Connections Figure 5-1. DMD2050E Universal Satellite Modem Front Panel Figure 5-2. DMD2050E Rear

Page 62 - 3.9 STANAG Turbo Coding

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–2 5.1 Power Connectors, Ground and Switches The DMD2050E units h

Page 63 - 3.10.1.1 Key Agreement

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–3 5.2 Front Panel Connections 5.2.1 Key Loader Interface Label

Page 64

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–4 5.3 Rear Panel Connectors CAUTION Before you connect any cab

Page 65

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–5 5.3.2 EXT REF (J10) Label Description Connector Type Input Lev

Page 66 - 3.10.1.2.1 Key Derivation

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–6 5.3.4 ALARM (J15) Label Description Connector Type ALARM J15

Page 67

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–7 5.3.4.1 IBS Network Alarms Configuration IBS Prompt Alarms IBS

Page 68

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E viii 4.5 Terminal Mode Control...

Page 69

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–8 5.3.6 ASYNC (J17) Label Description Connector Type ASYNC J17

Page 70

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–9 5.3.8 MIL-188-114A (J19) Label Description Connector Type MI

Page 71 - DMD2050E CnC Module

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–10 5.3.9 Monitor and Control Connectors J20, J21 Label Descript

Page 72

MN-DMD2050E Revision 2 6–1 Chapter 6. Maintenance and Troubleshooting 6.1 Periodic Maintenance 6.1.1 Battery Replacement WARNING: DANGER OF EX

Page 73

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–2 6.2 Troubleshooting 6.2.1 Basic Troubleshooting Pro

Page 74

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–3 6.3 Alarms 6.3.1 Major Transmit Alarms Alarm Desc

Page 75

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–4 Alarm Description Status INPUT LVL THRESH Indicates t

Page 76

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–5 Alarm Description Status TPC CONFLICT CHK Indicates t

Page 77 - 3.11.6 Margin Requirements

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–6 Alarm Description Status RX AGC LEVEL Indicates Rx le

Page 78

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–7 Alarm Description Status +3.3V SUPPLY Shows the measu

Page 79

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E ix 6.4 Alarm Masks ...

Page 80

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–8 6.4 Alarm Masks The DMD2050E self-monitors and isola

Page 81

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–9 Alarms are grouped into transmit and receive alarms.

Page 82

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–10 RX MAJOR (menu) {Pass/Fail} RX MINOR (menu) {Pass/Fa

Page 83

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–11 NOTE These alarms show the status of the alarms RE

Page 84

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–12 6.5 IBS Alarms and Actions Figure 6-1 and Table 6-1

Page 85

MN-DMD2050E Revision 2 7–1 Chapter 7. Technical Specifications 7.1 Modulator Modulator Specifications Modulation BPSK, QPSK, OQPSK, 8-PSK, 8-QA

Page 86

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–2 Modulator Specifications Turbo (16-QAM) {3/4, 7/8} ≤ 20Mb

Page 87

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–3 Demodulator Specifications Turbo (OQPSK/QPSK) {1/2, 3/4, 7

Page 88

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–4 7.5 Terrestrial Interfaces MIL-188-114A, HSSI GiGE 10/100/

Page 89

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–5 7.11 Data Rate Limits 7.11.1 Non-DVB Non-DVB Data Rate Li

Page 90

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E x 7.12.14 B/O/QPSK BER Performance (LDPC) ...

Page 91 - 3.11.15 Glossary

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–6 Non-DVB Data Rate Limits Modulation Code Rate Min Data Rate

Page 92

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–7 7.11.2 DVB DVB Data Rate Limits Modulation Code Rate DVB M

Page 93

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–8 DVB Data Rate Limits Modulation Code Rate DVB Mode Min Data

Page 94 - 3.12.1 LDPC versus TPC

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–9 7.12 BER Specifications 7.12.1 BER Performance (Viterbi)

Page 95

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–10 7.12.2 BER Performance (Sequential) Figure 7-2. DMD2050E

Page 96

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–11 7.12.3 BER Performance (Viterbi with Reed-Solomon) Figur

Page 97

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–12 7.12.4 BER Performance (Turbo) Figure 7-4. DMD2050E B/O

Page 98 - 3.13 Reed-Solomon Codec

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–13 7.12.5 BER Performance (8PSK Trellis) Figure 7-5. DMD20

Page 99 - 3.13.3 Interleaving

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–14 7.12.6 BER Performance (8PSK Turbo) Figure 7-6. DMD2050E

Page 100 - Communications)

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–15 7.12.7 BER Performance (16QAM Viterbi) Figure 7-7. DMD20

Page 101

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E xi D.2.2 IP Address ...

Page 102 - 3.16 Standard IBS Mode

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–16 7.12.8 BER Performance (16QAM Viterbi with Reed-Solomon)

Page 103 - 3.18 ESC Backward Alarms

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–17 7.12.9 BER Performance (16QAM Turbo) Figure 7-9. DMD2050

Page 104 - See also:

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–18 7.12.10 BER Performance (OQPSK Turbo) Figure 7-10. DMD2

Page 105

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–19 7.12.11 BER Performance (BPSK Turbo) Figure 7-11. DMD20

Page 106 - 3.19.2 Aggregate Data Rate

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–20 7.12.12 BER Performance (8PSK Turbo) Figure 7-12. DMD20

Page 107

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–21 7.12.13 BER Performance (16QAM Turbo) Figure 7-13. DMD2

Page 108 - (less than In-Band Rate)

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–22 7.12.14 B/O/QPSK BER Performance (LDPC) Figure 7-14. DM

Page 109

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–23 7.12.15 8PSK / 8QAM BER Performance (LDPC) Figure 7-15.

Page 110 - Port labeled ASYNC (J17)

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–24 7.12.16 16QAM BER Performance (LDPC) Figure 7-16. DMD205

Page 111

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–25 7.12.17 BER Performance B/O/QPSK (MILSTD 188-165B or STAN

Page 113 - Chapter 4. User Interfaces

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E xii E.4.3.3 PCM-31 ...

Page 114 - 4.2.3 Numeric Keys

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–26 7.12.18 BER Performance 8-PSK (MILSTD 188-165B or STANAG)

Page 115 - 4.2.4 LED Lights

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–27 7.12.19 BER Performance 16APSK (MILSTD 188-165B or STANAG

Page 116 - 4.4 Front Panel Main Menus

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–28 1/2 Rate 3/4 Rate 7/8 Rate 1/2 Rate 3/4 Rate 7/8 Ra

Page 117 - 4.4.1.1 NETWORK SPEC (menu)

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–29 Turbo 0.495 Turbo 0.793 Turbo 0.495 Turbo 0.7931E-3

Page 118 - 4.4.1.4 DATA (menu)

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–30 3/4 Rate 7/8 Rate 3/4 Rate 7/8 Rate1E-3 8.9 dB 10.3

Page 119

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–31 1/2 Rate 3/4 Rate 7/8 Rate 1/2 Rate 3/4 Rate 7/8

Page 120

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–32 1/2 Rate 2/3 Rate 3/4 Rate 1/2 Rate 2/3 Rate 3/4 R

Page 121 - 4.4.1.6 AUPC (menu)

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–33 1/2 Rate 2/3 Rate 3/4 Rate 7/8 Rate19/20 Rate1/2 Rate

Page 122 - 4.4.1.7 LOCAL AUPC (menu)

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–34 7.13 AGC Output Voltage The AGC Output Voltage is a funct

Page 123

MN-DMD2050E Revision 2 A–1 Appendix A. Product Options A.1 Hardware Options These enhanced interface cards are available: DC Input Prime Power

Page 124

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E xiii APPENDIX H. ETHERNET DATA INTERFACE SETUP...

Page 125 - 4.4.1.9 ITA (menu)

DMD2050E Universal Satellite Modem Product Options MN-DMD2050E Revision 2 A–2 BLANK PAGE

Page 126 - 4.4.2.1 NETWORK SPEC (menu)

MN-DMD2050E Revision 2 B–1 Appendix B. Front Panel Upgrades and Demonstration Mode B.1 Introduction The DMD2050E Universal Satellite Modem allow

Page 127 - 4.4.2.3 IF (menu)

DMD2050E Universal Satellite Modem Front Panel Upgrade Procedure MN-DMD2050E Revision 2 B–2 B.3.1 Record the Features and Options Find and record

Page 128 - 4.4.2.4 DATA (menu)

DMD2050E Universal Satellite Modem Front Panel Upgrade Procedure MN-DMD2050E Revision 2 B–3 B.3.2 Record the Unit ID Comtech requests the Unit ID

Page 129 - 4.4.2.5 REED-SOLOMON (menu)

DMD2050E Universal Satellite Modem Front Panel Upgrade Procedure MN-DMD2050E Revision 2 B–4 B.3.4 Install the Code Use the front panel to enter t

Page 130 - Hz) between the

DMD2050E Universal Satellite Modem Front Panel Upgrade Procedure MN-DMD2050E Revision 2 B–5 B.3.5 Demonstration Mode Considerations The unit uses

Page 131 - 4.4.3.1 TX SETUP (menu)

DMD2050E Universal Satellite Modem Front Panel Upgrade Procedure MN-DMD2050E Revision 2 B–6 B.3.6 Cancel the Demonstration Mode IMPORTANT If you

Page 132

MN-DMD2050E Revision 2 C–1 Appendix C. Carrier Control C.1 Carrier Control and Alarms If a TX major alarm occurs, modulator output is muted auto

Page 133

DMD2050E Universal Satellite Modem Carrier Control MN-DMD2050E Revision 2 C–2 C.3 Carrier States These are the carrier states: • Carrier OFF •

Page 134 - 4.4.3.2 RX SETUP (menu)

DMD2050E Universal Satellite Modem Carrier Control MN-DMD2050E Revision 2 C–3 2. The output starts again automatically. C.3.4 Carrier VSAT The ca

Page 135

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E xiv Tables Table 3-1. Spectral Efficiency using DoubleTalk Carrier-

Page 136 - 4.4.3.3 GENERAL (menu)

DMD2050E Universal Satellite Modem Carrier Control MN-DMD2050E Revision 2 C–4 BLANK PAGE

Page 137 - 4.4.4.1 LINK STATUS (menu)

MN-DMD2050E Revision 2 D–1 Appendix D. Web Interface Setup Guide D.1 Introduction The web interface lets Radyne products connect and communicate

Page 138

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–2 D.2.2 IP Address IMPORTANT Before you set an IP address, c

Page 139 - 4.4.4.4 ITA (menu)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–3 D.3.2 User Account Data IMPORTANT All entries are case-sen

Page 140 - 4.4.6.2 REMOTE CONTROL

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–4 IMPORTANT All entries are case-sensitive. To set up a Use

Page 141 - 4.4.6.5 TCP/IP (menu)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–5 D.2 Reset a User Account Sometimes, it is necessary to rese

Page 142

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–6 D.4 Equipment Website Once you know that the modem is acces

Page 143 - 4.4.6.6 SNMP (menu)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–7 The Introduction page shows general information, such as: •

Page 144 - 4.4.6.8 WEB (menu)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–8 D.5 Web Page Appearance This page displays the Monitor and

Page 145 - 4.4.6.9 TRANSEC (menu)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–9 D.6 Configure Web Browsers for the Radyne WEB Interface D

Page 146

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E xv Figures Figure 1-1. DMD2050E Universal Satellite Modem Front Pa

Page 147 - 4.4.6.10.2 FEATURES (menu)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–10 D.6.2.1 Change the encoding: Click View on the Firefox men

Page 148

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–11 D.6.2.2 Install the Internet Explorer Tab V2 add-on The In

Page 149

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–12 D.6.3 Configure Chrome for the Radyne WEB Browser When you

Page 150 - 4.5.1 Terminal Mode Screens

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–13 D.6.3.1 Change the encoding On the Chrome address bar, cli

Page 151

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–14 D.6.3.2 Install the Internet Explorer Tab for Chrome The I

Page 152

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–15 D.6.4 Configure Safari for the Radyne WEB Browser IMPORTA

Page 153

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–16 D.6.4.2 Reset the Ethernet M&C port To reset the Ether

Page 154 - 5.1.2 Power Switch

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–17 On the Monitor & Control, Password Setup or IP Administ

Page 155 - 5.2.1 Key Loader Interface

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–18 D.6.4.4 Change the encoding Click View on the Safari menu

Page 156 - 5.3 Rear Panel Connectors

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–19 D.6.5 Configure Maxthon for the Radyne WEB Browser On the

Page 157 - 5.3.2 EXT REF (J10)

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E xvi Figure D-3. Monitor and Control Web Page ...

Page 158 - 5.3.4 ALARM (J15)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–20 D.6.5.1 Change the browser mode Two browser modes are poss

Page 159 - 5.3.5 EXT CLK (J16)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–21 D.6.5.2 Change the encoding On the Monitor & Control p

Page 160 - 5.3.6 ASYNC (J17)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–22 BLANK PAGE

Page 161 - 5.3.8 MIL-188-114A (J19)

MN-DMD2050E Revision 2 E–1 Appendix E. Drop and Insert (Standard and Efficient Options) E.1 Introduction Drop and Insert (D&I) functions

Page 162

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–2 Objective Menu Path Requirement Find the G.703 interface c

Page 163 - Troubleshooting

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–3 Figure E-1. Looped Modems Figure E-2 Looped Modems wi

Page 164 - 6.2 Troubleshooting

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–4 E.4 Functional Descriptions E.4.1 Drop Only When Drop is

Page 165 - 6.3.2 Major Rx Alarms

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–5 Figure E-4 Insert Only with Eternal Frame Source Figure

Page 166 - 6.3.3 Minor Tx Alarms

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–6 E.4.3 Data Formats The terrestrial data formats compatibl

Page 167 - 6.3.3.1 Minor Rx Alarms

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–7 drop and n timeslots to insert where n = 1, 2, 3, 4, 5, 6,

Page 168

xix PREFACE About this Manual This manual gives installation and operation information for the Comtech EF Data DMD2050E Universal Product Modem.

Page 169

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–8 SATCh TS Enter to Edit Any changes made in these displa

Page 170 - 6.4.1.2 Minor Alarms

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–9 Example : For a modem w/ Drop and Insert enabled at a data

Page 171 - 6.4.3 Latched Alarms

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–10 Map Copy RX EDIT > RX ACTIVE 4. Press &l

Page 172

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–11 E.5.1 Data Rate Data Rate affects the Drop and Insert fu

Page 173 - 6.4.4 Backward Alarms

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–12 n = 12, data rate = 768000 n = 15, data rate = 960000 n =

Page 174 - 6.5 IBS Alarms and Actions

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–13 E.5.3.1 Insert Terrestrial Frame Source The Insert Terre

Page 175 - 7.1 Modulator

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–14 Under Tx D&I: Set Drop Mode = T1-D4

Page 176 - 7.2 Demodulator

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–15 Set Conv Enc = 3/4 Rate VIT Under Interface: Unde

Page 177 - 7.4 Monitor and Control

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–16 Set Rx Type according to your hardware configuration

Page 178

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–17 E.5.4.1 D&I Clock Setup Examples Figure E-7 Trans

Page 179 - 7.11.1 Non-DVB

DMD2050E Universal Product Modem Revision 2 Preface MN-DMD2050E xx Electrical Safety The DMD2050E has been shown to comply with the EN 60950 Safety

Page 180

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–18 Figure E-9 Rx Only With Trunk Figure E-10 Rx Only No

Page 181 - 7.11.2 DVB

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–19 E.6 D&I Maps and Map Editing The Drop and Insert mul

Page 182

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–20 Therefore, in this case only the first six entries of the

Page 183 - 7.12 BER Specifications

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–21 map through the modem’s LCD; when editing is complete, th

Page 184 -

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–22 time slots of the T1 or E1 frame. The Multiplexer would

Page 185 - Viterbi Decoder Reed

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–23 This would be used with T1 frames where channels 1 throug

Page 186 - Turbo Decoder

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–24 E.8 Prerequisite In order for a modem to be configured f

Page 187 - Trellis

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–25 E.9 Efficient Drop and Insert Mode With Efficient Drop a

Page 188

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–26 600 station in-band rate. In most cases, this

Page 189 - Viterbi

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–27 E.9.4 Calculating the Efficient D&I Rate with Enhanc

Page 190 - Reed Solomon

DMD2050E Universal Product Modem Revision 2 Preface MN-DMD2050E xxi Environmental Do not operate the DMD2050E in an environment where the unit is ex

Page 191

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–28 X = Truncation of (1.92) X = 1 Add 1 * 5 * 125 bps to

Page 192

MN-DMD2050E Revision 2 F–1 Appendix F. TCP/IP Ethernet Setup F.1 Introduction The modem supports SNMP, FTP protocols and the Web Browser. Utili

Page 193

DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup MN-DMD2050E Revision 2 F–2 • MODEM IP ADDR 010.000.000.001 • SERVER IP ADDR 010.0

Page 194

DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup MN-DMD2050E Revision 2 F–3 and loop back addresses will not be allowed. Example Server I

Page 195

DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup MN-DMD2050E Revision 2 F–4 F.4 Ethernet Test F.4.1 Connecting the Modem Ethernet Cable

Page 196 - LDPC Decoder

DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup MN-DMD2050E Revision 2 F–5 1. Click the Start button. 2. Select Settings and click Co

Page 197

DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup MN-DMD2050E Revision 2 F–6 Internet Protocol (TCP/IP) Properties 9. Select “Use the fo

Page 198

DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup MN-DMD2050E Revision 2 F–7 F.5 Testing the Ethernet Connection using the Ping Program (O

Page 199

DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup MN-DMD2050E Revision 2 F–8 4. If the ping is unsuccessful the screen will display: C:\>

Page 200 - MILSTD 188-165B

MN-DMD2050E Revision 2 G–1 Appendix G. AUPC Operation G.1 Automatic Uplink Power Control (AUPC Operation) The modem has an optional built-in pro

Page 201 - MILSTD 188

DMD2050E Universal Product Modem Revision 2 Preface MN-DMD2050E xxii CE Mark Comtech EF Data declares that the DMD2050E meets the necessary requirem

Page 202

DMD2050E Universal Satellite Modem AUPC Operation MN-DMD2050E Revision 2 G–2 drop in the remote Eb/No, it slowly begins to raise the output power,

Page 203

DMD2050E Universal Satellite Modem AUPC Operation MN-DMD2050E Revision 2 G–3 The local receiver must be tuned and locked to the transmitter and th

Page 204

DMD2050E Universal Satellite Modem AUPC Operation MN-DMD2050E Revision 2 G–4 When the rain diminishes, Local modem will see the remote Es/No begin

Page 205

MN-DMD2050E Revision 2 H–1 Appendix H. Ethernet Data Interface Setup H.1 Configuring the modem to use the Ethernet Data Interface (Optional) Whe

Page 206

DMD2050E Universal Satellite Modem Ethernet Data Interface Setup MN-DMD2050E Revision 2 H–2 When Ethernet Data Interface is selected, the Tx Clock

Page 207

DMD2050E Universal Satellite Modem Ethernet Data Interface Setup MN-DMD2050E Revision 2 H–3 When Port 4 is selected for Daisy Chain, any data rece

Page 208 - 7.13 AGC Output Voltage

DMD2050E Universal Satellite Modem Ethernet Data Interface Setup MN-DMD2050E Revision 2 H–4 H.1.5 Setting Up The DMD2050E Ethernet Bridge To Opera

Page 209 - Appendix A. Product Options

DMD2050E Universal Satellite Modem Ethernet Data Interface Setup MN-DMD2050E Revision 2 H–5 H.1.6 Packet Statistics The following statistics are a

Page 210

DMD2050E Universal Satellite Modem Ethernet Data Interface Setup MN-DMD2050E Revision 2 H–6 BLANK PAGE

Page 211 - B.3 Procedures

MN-DMD2050E Revision 2 I–1 Appendix I. Strap Codes I.1 Strap Codes The Strap Code is a quick set key that sets many of the modem parameters. For

Page 212

DMD2050E Universal Product Modem Revision 2 Preface MN-DMD2050E xxiii Product support On the web http://www.comtechefdata.com/support.asp Return mat

Page 213 - B.3.2 Record the Unit ID

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–2 NOTE Dis = Disable in Table I-1. Table I-1. Strap Codes Strap Code (D

Page 214 - B.3.4 Install the Code

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–3 Strap Code (Decimal) Data Rate (Kbps) Overhead Code Rate Type Framing Ty

Page 215

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–4 Strap Code (Decimal) Data Rate (Kbps) Overhead Code Rate Type Framing Ty

Page 216

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–5 Strap Code (Decimal) Data Rate (Kbps) Overhead Code Rate Type Framing Ty

Page 217 - Appendix C. Carrier Control

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–6 I.2 Sample Applications The following section provides brief applicatio

Page 218 - C.3.3 Carrier AUTO

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–7 I.2.1 Operational Case Examples IMPORTANT Make sure to set the data r

Page 219 - C.3.5 CARRIER RTS

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–8 Set desired Tx frequency and power level Turn IF on Demodulator

Page 220

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–9 I.2.1.2 Case 2: IBS 1.544 Mbps, 3/4 Rate Viterbi Start with the Data R

Page 221 - Setup Guide

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–10 Demodulator: Method 1 - Under Interface Menu: Set Interface type Se

Page 222 - D.3.1 Default User Accounts

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–11 I.2.1.3 Case 3: Closed Network, 3/4 Rate Viterbi, IBS Overhead Start

Page 223 - D.1 User Account Setup

ER-DMD2050E-EA2 Rev - PLM C-0028800 Errata A for MN-DMD2050E Rev 2 Comtech EF Data Documentation Update Subject: Chapter 3, Theory of Operati

Page 224 - D.1.2 Edit the Access Group

DMD2050E Universal Product Modem Revision 2 Preface MN-DMD2050E xxiv Warranty Policy Comtech EF Data products are warranted against defects in mater

Page 225 - D.3 Confirmation

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–12 Demodulator: Method 1 - Under Interface Menu: Set Interface type Se

Page 226 - D.4 Equipment Website

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–13 I.2.1.4 Case 4: Loop Timing Example Method 1 - Under Interface Menu:

Page 227

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–14 BLANK PAGE

Page 228 - D.5 Web Page Appearance

MN-DMD2050E Revision 2 J–1 Appendix J. ITA Operation J.1 Information Throughput Adaptation (ITA Operation) Information Throughput Adaptation (IT

Page 229

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–2 J.1.1 Properties of ITA on the DMD2050E: • The DMD2050E output power

Page 230

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–3 J.1.2 Basic Setup (Example) The modems will be initially configured i

Page 231

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–4 J.1.2.1 Initial DMD2050E Modem Setup Table J-2 - Initial Modem Setup

Page 232

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–5 Figure J-1 - Initial Setup DMD2050E, Modulator IF

Page 233 - D.6.3.1 Change the encoding

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–6 Figure J-2 - Initial Setup DMD2050E, Modulator Data

Page 234

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–7 Figure J-3 - Initial Setup DMD2050E, Modulator ITA

Page 235

MN-DMD2050E Revision 2 1– 1 Chapter 1. Introduction 1.1 Overview The new DMD2050E Satellite Modem (Figure 1-1) breaks new ground in flexibility a

Page 236

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–8 Figure J-4 - Initial Setup DMD2050E, Demodulator IF

Page 237

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–9 Figure J-5 - Initial Setup DMD2050E, Demodulator Data

Page 238 - D.6.4.4 Change the encoding

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–10 Figure J-6 - Initial Setup DMD2050E, Demodulator ITA At this point

Page 239

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–11 Table J-3 - ITA Setup FW: F05280-AH28 REV 4.4.28 (7/06 9:47)MAIN

Page 240

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–12 The ITA Menu Functions and their descriptions are shown in Table J-4

Page 241 - D.6.5.2 Change the encoding

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–13 Table J-5. Receive ITA Functions Function AUPC Available Options Desc

Page 242

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–14 Table J-6 – ITA Waveform Masks (Modulator UUT) DMD2050E MENU SETTINGS

Page 243 - E.2 System Requirements

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–15 Table J-7 – ITA Waveform Masks (Demodulator UUT) DMD2050E MENU SETTIN

Page 244 - E.3 Configuration Examples

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–16 Table J-8 – ITA Waveform Masks (Reference Modulator) DMD2050E MENU SE

Page 245 - Figure E-1. Looped Modems

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–17 Table J-9 – ITA Waveform Masks (Reference Demodulator) DMD2050E MENU

Page 246 - E.4.2 Insert Only

DMD2050E Universal Product Modem Introduction MN-DMD2050E Revision 2 1– 2 The DMD2050E supports a full range of Industry Standard Interfaces that i

Page 247

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–18 Figure J-7 - Initial Setup DMD2050E, Modulator ITA

Page 248 - E.4.3.3 PCM-31

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–19 Figure J-8 - Initial Setup DMD2050E, Demodulator ITA To setup ITA Mo

Page 249 - E.4.3.6 T1-ESF/T1-ESF-S

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–20 Figure J-9- Initial Setup DMD2050E, Modulator ITA (Enabled)

Page 250

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–21 Figure J-10 - Initial Setup DMD2050E, Demodulator ITA (Enabled)

Page 251

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–22 Figure J-11 –DMD2050E I/Q for BPSK 2/3

Page 252

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–23 Figure J-12 –DMD2050E ITA Status for QPSK 2/3

Page 253 - E.5.1 Data Rate

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–24 Figure J-13 –DMD2050E I/Q for QPSK 2/3

Page 254

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–25 Figure J-14 –DMD2050E ITA Status for 16APSK 1/2

Page 255 - Example 1:

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–26 Figure J-15 –DMD2050E I/Q for 16APSK 1/2

Page 256

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–27 Figure J-16 –DMD2050E ITA Status for 8PSK 3/4

Page 257 - Example 2:

DMD2050E Universal Product Modem Introduction MN-DMD2050E Revision 2 1– 3 • Switchable between spur-free 70/140 MHz and L-Band operations • AC or

Page 258

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–28 Figure J-17 –DMD2050E I/Q for 8PSK 3/4

Page 259

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–29 Figure J-18 –DMD2050E ITA Status for 16APSK 7/8

Page 260

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–30 Figure J-19 –DMD2050E I/Q for 16APSK 7/8 At this point changing the

Page 261

Copyright © Comtech EF Data, 2011. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.

Page 262

Licensed Software Revision 0 TRANSEC Module AD-TRANSEC-LICNS 2 GNU GENERAL PUBLIC LICENSE Version 2, June 1991 Copyright (C) 1989, 1991

Page 263

Licensed Software Revision 0 TRANSEC Module AD-TRANSEC-LICNS 3 either of that version or of any later version published by the Free Software Founda

Page 264

Licensed Software Revision 0 TRANSEC Module AD-TRANSEC-LICNS 4 writing it). Whether that is true depends on what the Library does and what the pro

Page 265

Licensed Software Revision 0 TRANSEC Module AD-TRANSEC-LICNS 5 It is not the purpose of this section to induce you to infringe any patents or other

Page 266 - E.8 Prerequisite

Licensed Software Revision 0 TRANSEC Module AD-TRANSEC-LICNS 6 * This can be in the form of a textual message at program startup or * in document

Page 267

Licensed Software Revision 0 TRANSEC Module AD-TRANSEC-LICNS 7 Darren Tucker Sun Microsystems The SCO Group * Redistribution and use in sou

Page 268

DMD2050E Universal Product Modem Introduction MN-DMD2050E Revision 2 1– 4 1.2.4 Interfaces Industry-standard interfaces include: • MIL-188-114 (

Page 269

Licensed Software Revision 0 TRANSEC Module AD-TRANSEC-LICNS 8 This page is intentionally blank.

Page 271 - F.1 Introduction

2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 • 333 • 2200 PHONE 480 • 333 • 2161 FAX

Page 272

DMD2050E Universal Product Modem Introduction MN-DMD2050E Revision 2 1– 5 1.2.7.1 Dimensional Envelope

Page 273

DMD2050E Universal Product Modem Introduction MN-DMD2050E Revision 2 1– 6 1.3 Configurations and Options The DMD2050E has several configuration p

Page 274 - Network)

MN-DMD2050E Revision 2 2–1 Chapter 2. Installation 2.1 Unpacking and Inspection CAUTION Do not damage the carton contents with a cutting tool.

Page 275

DMD2050E Universal Satellite Modem Installation MN-DMD2050E Revision 2 2–2 2.2 Installation Safety The unit is shipped fully assembled. Do not r

Page 276

DMD2050E Universal Satellite Modem Installation MN-DMD2050E Revision 2 2–3 2.3.1 Location The unit is intended for indoor use only. Do not instal

Page 277

ER-DMD2050E-EA2 Rev - PLM C-0028800 Blank Page

Page 278

DMD2050E Universal Satellite Modem Installation MN-DMD2050E Revision 2 2–4 2.3.5 Cables To meet EMC directives, make sure to use shielded cables

Page 279 - Appendix G. AUPC Operation

DMD2050E Universal Satellite Modem Installation MN-DMD2050E Revision 2 2–5 IMPORTANT Strap Code 26 can set the following modem configuration. T

Page 280 - G.1.3 Near Side AUPC

DMD2050E Universal Satellite Modem Installation MN-DMD2050E Revision 2 2–6 BLANK PAGE

Page 281 - G.1.4 EBEM AUPC

MN-DMD2050E Revision 2 3–1 Chapter 3. Theory of Operation 3.1 DMD2050E Hardware The DMD2050E is based on a two printed circuit card (minimum con

Page 282

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–2 3.1.1 DMD2050E L-Band/IF Printed Circuit Card The L-Band/IF Pri

Page 283 - Interface Setup

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–3 3.1.2 DMD2050E Baseband Processing Printed Circuit Card The adv

Page 284 - H.1.2 Ethernet Daisy Chain

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–4 Figure 3-3. DMD2050E Baseband Processing Card Block Diagram The

Page 285 - H.1.4 Ethernet QOS Queue

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–5 The M&C System is based on a powerful microprocessor with a

Page 286

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–6 Figure 3-4. DMD2050E Universal Satellite Modem Functional Block

Page 287 - H.1.6 Packet Statistics

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–7 The Reed-Solomon Encoder, encodes the data into Reed-Solomon Blo

Page 288

ER-DMD2050E-EB2 Rev - PLM C-0028804 Errata B for MN-DMD2050E Rev 2 Comtech EF Data Documentation Update Subject: Chapter 3 and Chapter 4 refe

Page 289 - Appendix I. Strap Codes

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–8 • Modem Status, Alarms & Contact Closures (Section 3.2.9) 3

Page 290

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–9 3.2.8 Ethernet M&C Port This port is dedicated for Ethernet

Page 291

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–10 3.3 Internal Clock The time and date is kept in order to ‘tim

Page 292

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–11 Figure 3-5. Loopback Functional Block Diagram

Page 293

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–12 Figure 3-6. Loopback Functional Block Diagram

Page 294 - I.2 Sample Applications

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–13 Figure 3-7. Loopback Functional Block Diagram 3.5 DMD2050E Cl

Page 295

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–14 SDTTTx CLKSRCHigh Stability OscillatorSTCLOCK & DATAEXT REF

Page 296

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–15 3.5.2.1 SCTE: Serial Clock Transmit External The SCTE clock is

Page 297

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–16 3.5.3 RX Buffer Clock Options The modem supports a number of

Page 298

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–17 3.5.3.3 SCT: Serial Clock Transmit If SCT clock is selected

Page 299

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–31 4.4.6.6 SNMP (menu) A description of OID organization is provided

Page 300

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–18 3.6 Transmit Timing Options As shown in Figure 3-7, Transmit T

Page 301

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–19 3.6.4 Ethernet Data Interface (Optional) The modem support a s

Page 302

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–20 3.8 Ebem Framing Unit The DMD2050E EBEM framing Unit provides

Page 303 - Appendix J. ITA Operation

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–21 3.10 FIPs TRANSEC Module The DMD2050E FIPS Security Module pro

Page 304

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–22 IdleWaiting for Embedded ChannelTX OFFEvent: TX ONAction: NoneW

Page 305 - J.1.2 Basic Setup (Example)

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–23 IdleWaiting for Key RolloverStartupEvent: Key Agreement Messag

Page 306

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–24 3.10.1.2 Key Agreement Algorithm The key agreement algorithm

Page 307

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–25 After you have enabled Encryption from the front panel, set up

Page 308

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–26 Figure 3-12. DMD2050E Handheld Key Loader 3.11 DoubleTalk Car

Page 309

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–27 3.11.1 What is DoubleTalk Carrier-in-Carrier? The DMD2050E Do

Page 310

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–8  Modem Status, Alarms & Contact Closures (Section 3.2.9) 3

Page 311

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–28 • The transponder needs to be “bent-pipe” – meaning no on-boar

Page 312

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–29 Figure 3-13. Conceptual Block Diagram In a number of ways, CnC

Page 313 - Table J-3 - ITA Setup

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–30 • The ratio of power spectral density is normally less than 11

Page 314

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–31 Figure 3-11 shows the same link using the DMD2050E equipped wi

Page 315

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–32 Traditional Full Duplex Link Duplex Link with Doub

Page 316

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–33 QPSK 3/4 1.50 3.00 QPSK 7/8 1.75 3.50 8-QAM 2/3 2.00 4.00

Page 317

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–34 Figure 3-17. DoubleTalk Carrier-in-Carrier Signals Referring t

Page 318

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–35 Unwanted interfering signal suppression of 30 dB or more has be

Page 319

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–36 involves trying different FEC and modulation combinations with

Page 320

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–37 Carrier-in-Carrier link design involved trying different Modul

Page 321

ER-DMD2050E-EB2 Rev - PLM C-0028804 Blank Page

Page 322

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–38 Link parameters and LST summary for QPSK, LDPC 2/3 with Carrier

Page 323

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–39 The link budget summary for the different MODCOD combinations i

Page 324

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–40 While the traditional link was based on QPSK, TPC 3/4 and requi

Page 325

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–41 3.11.9.3 Power Limited Links Carrier-in-Carrier can provide su

Page 326

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–42 Whereas the original link used 8-PSK TPC 3/4, the Carrier-in-Ca

Page 327

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–43 Step Procedure 1c Make sure CnC function is OFF at both sites.

Page 328

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–44 3.11.11 Validating Carrier-in-Carrier Performance Carrier-in-C

Page 329

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–45 3.11.12 Operational References 3.11.12.1 Carrier-in-Carrier L

Page 330

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–46 3.11.12.2 Estimating PSD Ratio PSD can be estimated from a lin

Page 331

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–47 3.11.12.4 Estimating PSD Ratio from Satmaster 3.11.12.5 Esti

Page 332

Copyright © Comtech EF Data, 2013. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.

Page 333 - TRANSEC Module

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–48 3.11.13 DoubleTalk Carrier-in-Carrier Specifications Operatin

Page 334

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–49 3.11.14 Carrier-in-Carrier Summary Comtech EF Data’s DoubleTal

Page 335

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–50 Leased bandwidth Almost all satellite operators charge for the

Page 336

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–51 C/N = C/No – 10 log B [where B is bandwidth in Hz] Eb/No = C/No

Page 337

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–52 exhibits inherently low decoding latency compared with TCC, and

Page 338

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–53 It can be seen from this graph that, for Code Rates above 3/4,

Page 339

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–54 Mode Code Rate/Modulation Lower Data Rate Limit (kbps) Upper Da

Page 340

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–55 Table 3-3. Comparison of all Comtech EF Data TPC and LDPC Modes

Page 341

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–56 3.12.2 TPC and LDPC Summary FOR AGAINST Exceptionally good BE

Page 342 - • 333 • 2161 FAX

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–57 When the signal is received and demodulated by the Receiving Mo