Comtech-ef-data DT-4500-A Series Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Comtech-ef-data DT-4500-A Series. Comtech EF Data DT-4500-A Series User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 162
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
IMPORTANT NOTE: The information contained in this document supersedes all previously
published information regarding this product. Product specifications are subject to change
without prior notice.
Part Number MN-DT4500A Revision 1
DT-4500-A Series
Downconverters
Installation and Operation Manual
Vue de la page 0
1 2 3 4 5 6 ... 161 162

Résumé du contenu

Page 1 - DT-4500-A Series

IMPORTANT NOTE: The information contained in this document supersedes all previously published information regarding this product. Product specif

Page 2

DT-4500-A Series Downconverters Revision 1 Table of Contents MN-DT4500A viii A.7.1.18 Equipment Type...

Page 3

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–14 6.4.5.2.2 Admin | SNMP The Administrator must u

Page 4

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–15 Click [Submit SNMP] to save. Otherwise, click [R

Page 5 - TABLE OF CONTENTS

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–16 Click [Change Configuration] to save. Otherwi

Page 6

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–17 6.4.5.3.2 Config | Ref Use this page to review

Page 7

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–18 6.4.5.3.3 Config | Pre-selects Use this page to

Page 8

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–19 6.4.5.3.4 Config | Utility Use this page to con

Page 9

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–20 • Next Reboot Image: Use the drop-down list to

Page 10

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–21 6.4.5.3.5 Config | Redundancy See Appendix B.

Page 11

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–22 6.4.5.4 Status Pages Use these pages to review

Page 12 - FIGURES

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–23 6.4.5.4.2 Status | Faults Use this read-only pa

Page 13

DT-4500-A Series Downconverters Revision 1 Table of Contents MN-DT4500A ix APPENDIX B. REDUNDANT SYSTEM OPERATION ...

Page 14

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–24 Notes:

Page 15 - PREFACE

A–1 Appendix A. REMOTE CONTROL A.1 Introduction This appendix describes the protocol and message command set for remote monitor and control of the D

Page 16 - Metric Conversion

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–2 intended) will reply. The Target enables its output line driver and transmits i

Page 17 - Operating Environment

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–3 For EIA-232 control, a direct EIA-232 cable connection is made to each converte

Page 18 - (2004/108/EC)

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–4 Example: 10V3 (Addresses the third converter controlled by the backup conve

Page 19 - Preface MN-DT4500A

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–5 A.5.5 Response Timeout A minimum of 500 milliseconds is provided before declar

Page 20 - Limitations of Warranty

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–6 Note: This appendix uses “/COM” for the generic case examples. Example: <

Page 21 - Exclusive Remedies

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–7 A.7 Command / Response Pairs A.7.1 Utility Commands A.7.1.1 Time Command Det

Page 22 - Contacting Comtech EF Data

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–8 A.7.1.4 Time Protocol Server Use the TPS command to set the Time Server IP add

Page 23

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–9 A.7.1.7 IP Address Use the IPA command to set the IP address and network prefi

Page 24

DT-4500-A Series Downconverters Revision 1 Table of Contents MN-DT4500A x TABLES Table 3-1. DT-4500-A Rear Panel External Connections ...

Page 25 - Chapter 1. INTRODUCTION

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–10 A.7.1.10 Baud Rate The default baud rate is 9600. Command Details Set Baud R

Page 26 - 1.2 Functional Description

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–11 A.7.1.14 Screen Saver Timeout This legacy command does not control any hardwa

Page 27 - 1.2.1 Applications

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–12 A.7.1.18 Equipment Type Equipment type is a query that retrieves the model nu

Page 28 - 1.2.3 Monitor & Control

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–13 A.7.1.21 Firmware Information This command returns information about the firm

Page 29 - 1.3.1 Physical Description

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–14 A.7.1.23 Application Identification The Application Identification (AID) comm

Page 30 - 1.3.2 Dimensional Envelope

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–15 A.7.2 Configuration Commands A.7.2.1 Frequency The default RF frequency of t

Page 31 - 1.3.3.2 Rear Panel

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–16 A.7.2.4 Mute The default RF mute state is ON (output is muted). Command Deta

Page 32 - Introduction MN-DT4500A

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–17 A.7.2.7 Auto Fault Recovery The converter output is muted automatically in t

Page 33

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–18 A.7.2.10 Clear Preset Configuration Use this command to clear a single preset

Page 34

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–19 A.7.3 Modes There are two modes of operation that may intersect: Redundant Mo

Page 35

DT-4500-A Series Downconverters Revision 1 Table of Contents MN-DT4500A xi Figure B-2. 1:1 Redundant Configuration Diagram – Single Source IF Out

Page 36

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–20 A.7.3.2 Automatic/Manual Mode This command provides for automatic switching b

Page 37

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–21 A.7.4 Status Commands Status commands retrieve configuration, maintenance and

Page 38

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–22 A.7.4.3 Utility Status Command Details Utility Status: <DEV/RUS_'cr&a

Page 39

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–23 A.7.4.6 Terminal Status Change The TSC_ command can be used to determine if t

Page 40

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–24 A.7.4.8 Packed Maintenance Status Packed Maintenance Status: <DEV/PACRMS_

Page 41

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–25 A.7.4.10 Packed Alarm Status Packed Alarm Status: <DEV/PACRAS_'cr&

Page 42

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–26 A.7.5 Stored Alarms Up to 100 alarms are date/time stamped and stored in memo

Page 43 - Chapter 2. INSTALLATION

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–27 A.7.6 Error Processing A.7.6.1 General Errors The following Error Responses

Page 44 - Installation MN-DT4500A

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–28 A.7.7 Command Summaries A.7.8 User Remote Command Summary Utility Commands

Page 45

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–29 Status Commands Retrieve Configuration Status <DEV/RCS_'cr' Ret

Page 46

DT-4500-A Series Downconverters Revision 1 Table of Contents MN-DT4500A xii This page is intentionally blank.

Page 47

DT-4500-A Series Downconverters Revision 1 Appendix A MN-DT4500A A–30 Notes:

Page 48

B–1 Appendix B. REDUNDANT SYSTEM OPERATION B.1 Introduction to Redundancy Operation The Comtech EF Data DT-4500-A Series Downconverters are configur

Page 49 - 2.4 Connect External Cables

DT-4500-A Series Downconverters Revision 0 Appendix B MN-DT4500A B–2 B.2 Backup Downconverter The "Daisy Chain" terminates in the backup

Page 50

DT-4500-A Series Downconverters Revision 0 Appendix B MN-DT4500A B–3 B.3 Redundant Configurations Comtech EF Data DT-4500-A Series Downconverter

Page 51 - CONNECTORS

DT-4500-A Series Downconverters Revision 0 Appendix B MN-DT4500A B–4 Figure B-1. 1:1 Redundant Configuration –Single Source IF Output w

Page 52

DT-4500-A Series Downconverters Revision 0 Appendix B MN-DT4500A B–5 Figure B-4. TSEQM Connection Locations Figure B-5. 1:

Page 53

DT-4500-A Series Downconverters Revision 0 Appendix B MN-DT4500A B–6 Figure B-7. Dual Source 1:N Redun

Page 54

DT-4500-A Series Downconverters Revision 0 Appendix B MN-DT4500A B–7 Figure B-8. Dual Source 1:N Redundan

Page 55

DT-4500-A Series Downconverters Revision 0 Appendix B MN-DT4500A B–8 B.4 Redundant System Configuration B.4.1 Redundant System Configuration Using

Page 56

DT-4500-A Series Downconverters Revision 0 Appendix B MN-DT4500A B–9 high-speed bus fault will result. This fault should clear when configuration is

Page 57

xiii PREFACE About this Manual This manual provides installation and operation information for the Comtech EF Data’s DT-4500-A Series Downconverte

Page 58

DT-4500-A Series Downconverters Revision 0 Appendix B MN-DT4500A B–10 Figure B-11 depicts the front panel displays after power has been turned off o

Page 59 - 3.3 Cable Connections

DT-4500-A Series Downconverters Revision 0 Appendix B MN-DT4500A B–11 B.4.1.3 Manual Configuration and Verification Figure B-12 shows the system wi

Page 60 - Module (RSM-XX)

DT-4500-A Series Downconverters Revision 0 Appendix B MN-DT4500A B–12 Figure B-13 shows the front panel displays after the backup has forced Downc

Page 61

DT-4500-A Series Downconverters Revision 0 Appendix B MN-DT4500A B–13 B.4.2 Redundant System Configuration using the 45xxA Web Server Interface Cha

Page 62

DT-4500-A Series Downconverters Revision 0 Appendix B MN-DT4500A B–14 • Chain Length (Backup Unit): Use the drop-down list to select N/A, or 1:1 th

Page 63 - Chapter 4. UPDATING FIRMWARE

DT-4500-A Series Downconverters Revision 0 Appendix B MN-DT4500A B–15 B.4.4 Redundancy Systems – Downconverter Removal and Replacement In a redundan

Page 64

DT-4500-A Series Downconverters Revision 0 Appendix B MN-DT4500A B–16 Notes:

Page 65

C–1 Appendix C. MAINTENANCE AND TROUBLESHOOTING C.1 Overview This appendix serves to assist operator and maintenance personnel in the checkout, main

Page 66

DT-4500-A Series Downconverters Revision 1 Appendix C MN-DT4500A C–2 C.2 Maintenance Testing The DT-4500-A Series Downconverters translate the inp

Page 67

DT-4500-A Series Downconverters Revision 1 Appendix C MN-DT4500A C–3 check for other module faults, and check all connections. If the fault still e

Page 68

DT-4500-A Series Downconverters Revision 1 Preface MN-DT4500A xiv Warnings, Cautions, and Notes A WARNING gives information about a possible hazard

Page 69 - OPERATION

DT-4500-A Series Downconverters Revision 1 Appendix C MN-DT4500A C–4 C.2.4 Converter I/O Modules The Converter I/O Modules (IOM or TSM) are installe

Page 70 - 5.1.2 LED Indicators

METRIC CONVERSIONS Units of Length Unit Millimeter Centimeter Inch Foot Yard Meter Kilometer Mile 1 millimeter 1 0.1 0.0394 0.0033 0.

Page 71 - 5.1.3 Keypad

2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 • 333 • 2200 PHONE 480 • 333 • 2161 FAX

Page 72 - 5.3 Main Menu

DT-4500-A Series Downconverters Revision 1 Preface MN-DT4500A xv The user should carefully review the following information: Safety and Compliance

Page 73 - 5.3.1.1 CONFIG: OUTPUT

DT-4500-A Series Downconverters Revision 1 Preface MN-DT4500A xvi European Union Radio Equipment and Telecommunications Terminal Equipment (R&TT

Page 74

DT-4500-A Series Downconverters Revision 1 Preface MN-DT4500A xvii International Symbols Symbol Definition Symbol Definition Alternating Current

Page 76

DT-4500-A Series Downconverters Revision 1 Preface MN-DT4500A xviii Warranty Policy Comtech EF Data products are warranted against defects in materi

Page 77 - 5.3.1.3 CONFIG: REDUNDANCY

DT-4500-A Series Downconverters Revision 1 Preface MN-DT4500A xix The warranty excludes any responsibility by Comtech EF Data Corporation for incide

Page 78

DT-4500-A Series Downconverters Revision 1 Preface MN-DT4500A xx Getting Help Contacting Comtech EF Data Contact Comtech EF Data for: • Technical

Page 79 - 5.3.1.5 CONFIG: COLDSTART

DT-4500-A Series Downconverters Revision 1 Preface MN-DT4500A xxi Returning a Product for Upgrade or Repair Step Task 1 Go to the Comtech EF Data H

Page 80 - 5.3.3.1 FAULTS: CURRENT

DT-4500-A Series Downconverters Revision 1 Preface MN-DT4500A xxii Notes:

Page 81

1–1 Chapter 1. INTRODUCTION 1.1 Overview Figure 1-1. DT-4500-A Series Downconverters (DT-4503-A shown) Comtech EF Data’s DT-4500-A Series Dow

Page 82 - 5.3.4.1 PRE-SELECTS: LOAD

DT-4500A Series Downconverters Revision 1 Introduction MN-DT4500A 1–2 1.2 Functional Description Figure 1-2 shows the DT-4500-A chassis with its

Page 83 - 5.3.5 UTILITY

DT-4500A Series Downconverters Revision 1 Introduction MN-DT4500A 1–3 1.2.1 Applications The downconverter operates over the RF frequency range wi

Page 84

DT-4500A Series Downconverters Revision 1 Introduction MN-DT4500A 1–4 1.2.2 RF Signal Conversion As a typical example of the RF signal processing,

Page 85 - 5.3.5.7 UTILITY: FIRMWARE

DT-4500A Series Downconverters Revision 1 Introduction MN-DT4500A 1–5 Remote control inputs are provided through the EIA-232C or EIA-485 communicat

Page 86

Copyright © Comtech EF Data, 2013. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.33

Page 87 - MANAGEMENT

DT-4500A Series Downconverters Revision 1 Introduction MN-DT4500A 1–6 1.3.2 Dimensional Envelope Dimensions are shown in inches and [millimeters].

Page 88 - 6.2 SNMP Interface

DT-4500A Series Downconverters Revision 1 Introduction MN-DT4500A 1–7 1.3.3 Downconverter Physical Features 1.3.3.1 Front Panel Figure 1-5. DT

Page 89 - 6.2.3 SNMP Traps

DT-4500A Series Downconverters Revision 1 Introduction MN-DT4500A 1–8 • Prime Power Switch – The on/off prime power switch is located on the rea

Page 90 - 6.3 45xxA Telnet Interface

DT-4500A Series Downconverters Revision 1 Introduction MN-DT4500A 1–9 Characteristic Specification External Reference Input 5 or 10 MHz @ +3 dBm O

Page 91

DT-4500A Series Downconverters Revision 1 Introduction MN-DT4500A 1–10 1.4.2 DT-4503/E-A C-Band Downconverter Characteristic Specification Frequen

Page 92 - 6.4.2 User Login

DT-4500A Series Downconverters Revision 1 Introduction MN-DT4500A 1–11 Characteristic Specification Test Points (Front Panel) RF Sample Type ‘SMA’

Page 93 - 6.4.3.3 Action Buttons

DT-4500A Series Downconverters Revision 1 Introduction MN-DT4500A 1–12 1.4.3 DT-4503-A, /D-A, /E-A C-Band Downconverters Characteristic Specificat

Page 94 - 6.4.3.5 Text or Data Entry

DT-4500A Series Downconverters Revision 1 Introduction MN-DT4500A 1–13 Characteristic Specification LED Indicators (Front Panel) Power On Green LE

Page 95 - 6.4.5.1.1 Home

DT-4500A Series Downconverters Revision 1 Introduction MN-DT4500A 1–14 1.4.4 DT-4510-A, /D-A, DT-4511-A, DT-4512-A, /E -A Ku-B and Downconverters

Page 96 - 6.4.5.1.2 Home

DT-4500A Series Downconverters Revision 1 Introduction MN-DT4500A 1–15 Characteristic Specification On Line Yellow LED Fault Red LED Stored Fault R

Page 97 - 6.4.5.1.3 Home

This page is intentionally blank.

Page 98 - 6.4.5.2.1 Admin

DT-4500A Series Downconverters Revision 1 Introduction MN-DT4500A 1–16 1.4.5 DT-4513-A, /E-A Ku-Band Downconverters Characteristic Specification F

Page 99 - Webpage Timeout

DT-4500A Series Downconverters Revision 1 Introduction MN-DT4500A 1–17 Characteristic Specification Test Points (Front Panel) RF Sample Type ‘SMA’

Page 100 - 6.4.5.2.2 Admin

DT-4500A Series Downconverters Revision 1 Introduction MN-DT4500A 1–18 Notes:

Page 101 - 6.4.5.3 Config Pages

2–1 Chapter 2. INSTALLATION 2.1 Unpacking and Inspecting the Shipment Figure 2-1. Unpacking and Inspecting the Shipment Th

Page 102

DT-4500-A Series Downconverters Revision 1 Installation MN-DT4500A 2–2 This equipment contains parts and assemblies sensitive to damage by Electr

Page 103 - 6.4.5.3.2 Config

DT-4500-A Series Downconverters Revision 1 Installation MN-DT4500A 2–3 Figure 2-2. Installing into a Rack Enclosure

Page 104 - Load Pre-Select

DT-4500-A Series Downconverters Revision 1 Installation MN-DT4500A 2–4 2.2.1 Installing the Optional Rear-Mounting Support Brackets Kit

Page 105 - 6.4.5.3.4 Config

DT-4500-A Series Downconverters Revision 1 Installation MN-DT4500A 2–5 Follow these steps to install the CEFD-style chassis kit: Step Task 1 Use

Page 106 - Part Number (read-only)

DT-4500-A Series Downconverters Revision 1 Installation MN-DT4500A 2–6 2.2.2 Installing the Bearingless Rack Slide Sets If the converter is to be

Page 107

DT-4500-A Series Downconverters Revision 1 Installation MN-DT4500A 2–7 2.3 Connect Prime Power Connection The detachable power cord mates with th

Page 108 - 6.4.5.4.1 Status

iii TABLE OF CONTENTS TABLE OF CONTENTS ...

Page 109 - 6.4.5.4.2 Status

DT-4500-A Series Downconverters Revision 1 Installation MN-DT4500A 2–8 Notes:

Page 110

3–1 Chapter 3. REAR PANEL CONNECTORS 3.1 Rear Panel Overview Figure 3-1 shows the DT-4500-A Series downconverter rear panel and its accessible conne

Page 111 - Appendix A. REMOTE CONTROL

DT-4500-A Series Downconverters Revision 1 Rear Panel Connectors MN-DT4500A 3–2 3.2 DT-4500-A External Connectors Location (Chapter Sect.) Ref Des

Page 112 - A.3.1 Direct Access

DT-4500-A Series Downconverters Revision 1 Rear Panel Connectors MN-DT4500A 3–3 3.2.1.2 Optional DC Power Connection A standard 2-circuit terminal

Page 113 - A.4.2 Virtual Address

DT-4500-A Series Downconverters Revision 1 Rear Panel Connectors MN-DT4500A 3–4 3.2.1.5 100BASE-TX Ethernet M&C Port (RJ-45) This is a standard

Page 114 - Appendix A MN-DT4500A

DT-4500-A Series Downconverters Revision 1 Rear Panel Connectors MN-DT4500A 3–5 3.2.1.7 J1 | COM1 EIA-485/232 Interface Connector (DB-9F) The J1 |

Page 115

DT-4500-A Series Downconverters Revision 1 Rear Panel Connectors MN-DT4500A 3–6 3.2.2 Module-mounted Connectors The information that follows pertai

Page 116 - A.6.6.2 Response Ending

DT-4500-A Series Downconverters Revision 1 Rear Panel Connectors MN-DT4500A 3–7 3.2.2.1 J3 | HSB (High Speed Bus) Connector (DB-25F) The J3 | HS

Page 117 - A.7.1.2 Date

DT-4500-A Series Downconverters Revision 1 Rear Panel Connectors MN-DT4500A 3–8 3.2.2.2 Switch Module IF, RF, and Loop Connectors The IF and RF inp

Page 118

DT-4500-A Series Downconverters Revision 1 Rear Panel Connectors MN-DT4500A 3–9 PSM Assemblies CEFD P/N Impedance Comments AS/0101-10 75 Switching,

Page 119 - A.7.1.9 Physical Address

DT-4500-A Series Downconverters Revision 1 Table of Contents MN-DT4500A iv 1.2 Functional Description ...

Page 120 - A.7.1.13 Screen Saver Mode

DT-4500-A Series Downconverters Revision 1 Rear Panel Connectors MN-DT4500A 3–10 3.3.1 Cable Connections – Standalone (Non-Redundant) Operation In

Page 121 - A.7.1.15 VFD Brightness

DT-4500-A Series Downconverters Revision 1 Rear Panel Connectors MN-DT4500A 3–11 3.3.2 Cable Connections – Redundant System Operation In subsystems

Page 122 - A.7.1.19 Part Number

DT-4500-A Series Downconverters Revision 1 Rear Panel Connectors MN-DT4500A 3–12 Notes:

Page 123 - A.7.1.22 Firmware Image

4–1 Chapter 4. UPDATING FIRMWARE 4.1 Introduction TO ENSURE OPTIMAL PERFORMANCE, IT IS IMPORTANT TO OPERATE THE DT-4500-A WITH ITS LATEST AVAILABLE

Page 124 - A.7.1.24 Force Reboot

DT-4500-A Series Downconverters Revision 1 Updating Firmware MN-DT4500A 4–2 4.2 Getting Started: Preparing for the Firmware Download Step Task 1 Id

Page 125 - A.7.2.3 Cold Start

DT-4500-A Series Downconverters Revision 1 Updating Firmware MN-DT4500A 4–3 4.3 Downloading and Extracting the Firmware Update Step Task 1 Downloa

Page 126 - A.7.2.6 Redundant Mute Mode

DT-4500-A Series Downconverters Revision 1 Updating Firmware MN-DT4500A 4–4 4.4 Performing the Ethernet FTP Upload Procedure Step Task 1 Connect t

Page 127 - A.7.2.9 Display All Presets

DT-4500-A Series Downconverters Revision 1 Updating Firmware MN-DT4500A 4–5 Step Task 6 Change the desired image to boot. From the DT-4500-A fron

Page 128

DT-4500-A Series Downconverters Revision 1 Updating Firmware MN-DT4500A 4–6 Notes:

Page 129 - A.7.3.1 Redundant Mode

5–1 Chapter 5. 0BFRONT PANEL OPERATION 5.1 Introduction Figure 5-1. DT-4500-A Front and Rear Panel Views Figure 5-1 identifies the ke

Page 130 - A.7.3.3 Backup Mode

DT-4500-A Series Downconverters Revision 1 Table of Contents MN-DT4500A v 3.3 Cable Connections ...

Page 131 - A.7.4.2 Maintenance Status

DT-4500-A Series Downconverters Revision 1 Front Panel Operation MN-DT4500A 5–2 prompt you to carry out a required action. The LEDs indicate, in a

Page 132 - A.7.4.4 Alarm Status

DT-4500-A Series Downconverters Revision 1 Front Panel Operation MN-DT4500A 5–3 5.1.3 Keypad The keypad comprises six individual keyswitches. The

Page 133

DT-4500-A Series Downconverters Revision 1 Front Panel Operation MN-DT4500A 5–4 5.2 2BOpening Screen DT_45XX –X SW VER X.X.X SN########

Page 134

DT-4500-A Series Downconverters Revision 1 Front Panel Operation MN-DT4500A 5–5 5.3.1 CONFIG (Configuration) OUTPUT REMOTE REDUNDANCY FAULTRE

Page 135

DT-4500-A Series Downconverters Revision 1 Front Panel Operation MN-DT4500A 5–6 5.3.1.2 CONFIG: REMOTE (Remote Control) Remote Control: Local S

Page 136 - A.7.5.3 List All Alarms

DT-4500-A Series Downconverters Revision 1 Front Panel Operation MN-DT4500A 5–7 CONFIG: Remote Control  ETHERNET  ADDRESS IP Address/Range:

Page 137 - A.7.6.4 Time-Outs

DT-4500-A Series Downconverters Revision 1 Front Panel Operation MN-DT4500A 5–8 You may view or edit the SNMP Write Community string. To edit, fir

Page 138 - A.7.7 Command Summaries

DT-4500-A Series Downconverters Revision 1 Front Panel Operation MN-DT4500A 5–9 5.3.1.3 CONFIG: REDUNDANCY 1:1 Redundancy is an optional feature

Page 139

DT-4500-A Series Downconverters Revision 1 Front Panel Operation MN-DT4500A 5–10 CONFIG: REDUNDANCY Auto/Manual CONVERTER 123456789ABC AUTO/MAN

Page 140

DT-4500-A Series Downconverters Revision 1 Front Panel Operation MN-DT4500A 5–11 In the "Daisy Chain" configuration, the backup downconv

Page 141 - SYSTEM OPERATION

DT-4500-A Series Downconverters Revision 1 Table of Contents MN-DT4500A vi CHAPTER 6. ETHERNET-BASED REMOTE PRODUCT MANAGEMENT ...

Page 142 - B.2.2 Detachable Modules

DT-4500-A Series Downconverters Revision 1 Front Panel Operation MN-DT4500A 5–12 5.3.2 MONITOR Three read-only information screens provide mon

Page 143 - Appendix B MN-DT4500A

DT-4500-A Series Downconverters Revision 1 Front Panel Operation MN-DT4500A 5–13 Conv Temperature = OK ▲ High Speed Bus = OK ▼ Press ENTER

Page 144

DT-4500-A Series Downconverters Revision 1 Front Panel Operation MN-DT4500A 5–14 If Yes is selected, the faults log is cleared and you are returne

Page 145 - RSM-XX Installed

DT-4500-A Series Downconverters Revision 1 Front Panel Operation MN-DT4500A 5–15 The read-only bottom line displays the operating parameters tha

Page 146

DT-4500-A Series Downconverters Revision 1 Front Panel Operation MN-DT4500A 5–16 5.3.5.2 UTILITY : DISP (VFD Display) VFD Display Brightness:

Page 147

DT-4500-A Series Downconverters Revision 1 Front Panel Operation MN-DT4500A 5–17 5.3.5.5 UTILITY: SLOPE Converter slope adjustment = 0.0 The d

Page 148

DT-4500-A Series Downconverters Revision 1 Front Panel Operation MN-DT4500A 5–18 UTILITY: FIRMWARE  INFO Firmware Info: BOOTROM IMAGE#1 IM

Page 149

6–1 Chapter 6. ETHERNET-BASED REMOTE PRODUCT MANAGEMENT 6.1 Introduction Ethernet-based remote management and control of the DT-4500-A is availabl

Page 150

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–2 6.1.1 Ethernet Management Interface Protocols F

Page 151

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–3 The following MIB files are associated with the D

Page 152

DT-4500-A Series Downconverters Revision 1 Table of Contents MN-DT4500A vii A.2.3 Ethernet (100BASE-TX) ...

Page 153 - Interface

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–4 fault occurs and when a fault clears. Which style

Page 154 - B.4.3 Offset Adjustment

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–5 An example of login and remote command/query exec

Page 155

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–6 Failure to enter the correct User name and Passwo

Page 156

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–7 6.4.3 45xxA Web Server Interface Operational Fea

Page 157 - TROUBLESHOOTING

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–8 6.4.3.4 Drop-down lists A drop-down list lets yo

Page 158 - Appendix C MN-DT4500A

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–9 6.4.5 45xxA Web Server Interface Page Descriptio

Page 159 - C.2.3.7 Temperature Fault

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–10 6.4.5.1.2 Home | Contact Use this page to see t

Page 160 - C.3 Spares

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–11 6.4.5.1.3 Home | Support For this page to oper

Page 161 - Units of Weight

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–12 6.4.5.2 Admin Pages The Administrator must use

Page 162 - • 333 • 2161 FAX

DT-4500-A Series Downconverters Revision 1 Ethernet-based Remote Product Management MN-DT4500A 6–13 Click [Change IP Address] to save. Otherwise, cl

Modèles reliés UT-4500-A Series

Commentaires sur ces manuels

Pas de commentaire