RCF6001C- or Ku-BandSatellite TerminalInstallation and Operation ManualTM082 Rev. 1.0September, 1999 - NOTICE -1999, Rad
Description RCF6001 Satellite TerminalPage 1-2 TM082 - Rev. 1.0The DMD2401 LB/ST operates at data rates up to 4.375 Mbps. Selection of any data rat
RCF6001 Satellite Terminal DescriptionTM082 - Rev. 1.0Page 1-3The topology of the network in both of these broadcast examples would typically be c
RCF6001 Satellite Terminal InstallationTM082 - Rev. 1 Page 2-1Section 2 - Installation2.0 Installation RequirementsThe DMD2401 LB/ST Modem is designe
Installation RCF6001 Satellite TerminalPage 2-2 TM082 - Rev. 1.0Table 2-1. DMD2401 LB/ST Rear Panel ConnectorsConnector ID Description FunctionJ1
RCF6001 Satellite Terminal InstallationTM082 - Rev. 1.0Page 2-3
Installation RCF6001 Satellite TerminalPage 2-4 TM082 - Rev. 1.0
RCF6001 Satellite Terminal InstallationTM082 - Rev. 1.0Page 2-5J3 – RS232 Terminal Port Tab
Installation RCF6001 Satellite TerminalPage 2-6 TM082 - Rev. 1.0J4 - RemoteThe RS-485 connection is for remote monitor and control of the modem.Refe
RCF6001 Satellite Terminal InstallationTM082 - Rev. 1.0Page 2-733 DF Demod Fault - OpenCollectorOutput27 CS-B Clear to Send B (+) Output11* DM-A D
RCF6001 Satellite Terminal MaintenanceTM082 - Rev. 1.0 Page 4-1 Section 3 – RCF6001 Satellite Terminal Operation3.0 Operating ProceduresOperation of t
Maintenance RCF6001 Satellite TerminalPage 4-2 TM082 - Rev. 1.0
RCF6001 Satellite Terminal MaintenanceTM082 - Rev. 1.0 Page 4-3 Table 3-1. Front Panel Controls and IndicatorsFigure 3-
Maintenance RCF6001 Satellite TerminalPage 4-4 TM082 - Rev. 1.0modified and pressing the terminal key of the option number. For example, to change
RCF6001 Satellite Terminal MaintenanceTM082 - Rev. 1.0 Page 4-53.5.1 Initial Power-Up⇒⇒ CAUTION: Before initial powerup of the DMD2401 LB/ST, it is a
Maintenance RCF6001 Satellite TerminalPage 4-6 TM082 - Rev. 1.0The AUPC menus are located under the Modulator Menu as shown schematically below:The
RCF6001 Satellite Terminal MaintenanceTM082 - Rev. 1.0 Page 4-7channel. The basic frame structure used by the multiplexer is that specified in the IES
Maintenance RCF6001 Satellite TerminalPage 4-8 TM082 - Rev. 1.0Bit 1 - ES to ES Data Channel This bit is routed directly to the ES to ES Data Chann
RCF6001 Satellite Terminal MaintenanceTM082 - Rev. 1.0 Page 4-9
RCF6001 Satellite Terminal Warranty PolicyTM082- Rev. 1.0 iiRADYNE COMSTREAM WARRANTY POLICYWarranty and ServiceRadyne ComStream (hereafter referred t
Maintenance RCF6001 Satellite TerminalPage 4-10 TM082 - Rev. 1.03.10 Front Panel Menu Selections
RCF6001 Satellite Terminal MaintenanceTM082 - Rev. 1.0 Page 4-11The front panel has seven top level menus as follows: Modulator, Demodulator, Interfa
Maintenance RCF6001 Satellite TerminalPage 4-12 TM082 - Rev. 1.0NOTE: The frequencies of the Block Upconverter (BUC) and LNB must be entered first
RCF6001 Satellite Terminal MaintenanceTM082 - Rev. 1.0 Page 4-13Clk PolarityNormalSCT SourceInternalTx Terr IntfRS422Rx SetupRx Ckt IDProvides entry o
Maintenance RCF6001 Satellite TerminalPage 4-14 TM082 - Rev. 1.0Sets the time base for the channel error rate measurement, used toestimate Eb/No. T
RCF6001 Satellite Terminal MaintenanceTM082 - Rev. 1.0 Page 4-15Minor TxTx ActivityTerrClk MaskIndicates no terrestrial clock activity.IntClk MaskIndi
Maintenance RCF6001 Satellite TerminalPage 4-16 TM082 - Rev. 1.0+5 PowerIndicates power supply voltage out of range.BatteryIndicates battery failur
RCF6001 Satellite Terminal MaintenanceTM082 - Rev. 1.0 Page 4-17+12 Power+5 PowerBatteryRAM/ROMM&C uProcRef PLLExt Ref LockExt EXC ActHS Ref MaskH
Maintenance RCF6001 Satellite TerminalPage 4-18 TM082 - Rev. 1.0Tx enables the TX pattern generatorRx enables the receive pattern checkerTx/Rx enab
RCF6001 Satellite Terminal MaintenanceTM082 - Rev. 1.0 Page 4-19Section 4 - Maintenance4.0 Periodic MaintenanceThe DMD2401 LB/ST L-Band satellite mode
Warranty Policy RCF6001 Satellite TerminalTM082 - Rev. 1 iiireceived by Radyne for the unit or product or service furnished or to be furni
Maintenance RCF6001 Satellite TerminalPage 4-20 TM082 - Rev. 1.04.2.2.1 Major AlarmsMajor alarms indicate a modem hardware failure. Major alarms m
RCF6001 Satellite Terminal MaintenanceTM082 - Rev. 1.0 Page 4-21
Maintenance RCF6001 Satellite TerminalPage 4-22 TM082 - Rev. 1.0
RCF6001 Satellite Terminal MaintenanceTM082 - Rev. 1.0 Page 4-23
Maintenance RCF6001 Satellite TerminalPage 4-24 TM082 - Rev. 1.0
RCF6001 Satellite Terminal MaintenanceTM082 - Rev. 1.0 Page 4-25
Maintenance RCF6001 Satellite TerminalPage 4-26 TM082 - Rev. 1.0
RCF6001 Satellite Terminal ODU InstallationTM082 - Rev. 1.0 Page 5-1Section 5 – Ku-Band Outdoor Unit Installation ProceduresIntroductionThis section p
ODU Installation RCF6001 Satellite TerminalPage 5-2 TM082 - Rev. 1.0Unpacking the Outdoor UnitEach product is completely assembled, tested and the
RCF6001 Satellite Terminal ODU InstallationTM082 - Rev. 1.0 Page 5-3Inventory the EquipmentThe equipment and accessories should be inspected for dama
ODU Installation RCF6001 Satellite TerminalPage 5-4 TM082 - Rev. 1.0Step 8. Failure to use the lower loss cable for extended lengths will result i
RCF6001 Satellite Terminal ODU InstallationTM082 - Rev. 1.0 Page 5-5Mounting the Typical 1, 2 or 4 Watt Outdoor UnitThe following diagram and instruc
ODU Installation RCF6001 Satellite TerminalPage 5-6 TM082 - Rev. 1.0Figure 5-1. ODU (BUC) Mounting ConfigurationBUC4.VSDLNB12788Feed Support5 6641
RCF6001 Satellite Terminal ODU InstallationTM082 - Rev. 1.0 Page 5-7Step 10. Radyne ComStream does not provide the OMT assembly. Radyne ComStream can
ODU Installation RCF6001 Satellite TerminalPage 5-8 TM082 - Rev. 1.0Interface Connections for the 1, 2, or 4 Watt ODU (BUC)The following describes
RCF6001 Satellite Terminal ODU InstallationTM082 - Rev. 1.0 Page 5-95. SSPA I/F / RS-485 / 48VdcFunction: Input for 48 Vdc Source and RS-485 communi
ODU Installation RCF6001 Satellite TerminalPage 5-10 TM082 - Rev. 1.0Mounting the Typical 8-Watt / 16-Watt Outdoor Unit (BUC)The following diagram
RCF6001 Satellite Terminal ODU InstallationTM082 - Rev. 1.0 Page 5-11Figure 5-3 8-Watt / 16-Watt ODU BUC Connector Details.16BUC.VSDODU (BUC)SSPA431
ODU Installation RCF6001 Satellite TerminalPage 5-12 TM082 - Rev. 1.0Function: Provides the serial interface for communications between the BUC a
RCF6001 Satellite Terminal ODU InstallationTM082 - Rev. 1.0 Page 5-13C-Band Outdoor Unit Installation ProceduresAbout this sectionThis section provid
RCF6001 Satellite Terminal Record of RevisionsTM082 - Rev. 1.0 ivRCF6001 C- or Ku-Band Satellite TerminalInstallation and Operation ManualTM082 - Reco
ODU Installation RCF6001 Satellite TerminalPage 5-14 TM082 - Rev. 1.0carrier. A full report of the damage should be made and a copy forwarded to R
RCF6001 Satellite Terminal ODU InstallationTM082 - Rev. 1.0 Page 5-15loss foam dielectric cable such as Belden 9914 is required. Such cable must have
ODU Installation RCF6001 Satellite TerminalPage 5-16 TM082 - Rev. 1.0Prodelin Antenna BUC Mounting Kit (C-band 3120-0004)The BUC mounting kit prov
RCF6001 Satellite Terminal ODU InstallationTM082 - Rev. 1.0 Page 5-17Figure 4-4. C-Band BUC to Prodelin Antenna Mounting ConfigurationWR229 GASKET44X
ODU Installation RCF6001 Satellite TerminalPage 5-18 TM082 - Rev. 1.0Step 38. Refer to Table 4-1 for parts list and Figures 4-1, 4-2 and 4-3 for a
RCF6001 Satellite Terminal ODU InstallationTM082 - Rev. 1.0 Page 5-19Table 4-8C-Band ODU (BUC) / Feed Parts List(3120-0004)Item # Part # Description
ODU Installation RCF6001 Satellite TerminalPage 5-20 TM082 - Rev. 1.0Figure 4-2 C-Band ODU (BUC) Mounting Configuration End View206205 2072X208202
RCF6001 Satellite Terminal ODU InstallationTM082 - Rev. 1.0 Page 5-21Interface Connections for the 5-Watt Ku-band ODU (BUC)The following describes th
ODU Installation RCF6001 Satellite TerminalPage 5-22 TM082 - Rev. 1.0SSPA - RS-485 / 48 VdcFunction: Input for 48 Vdc Source and RS-485 communica
RCF6001 Satellite Terminal ODU InstallationTM082 - Rev. 1.0 Page 5-23Mounting the Typical C-Band High Power Outdoor Unit AssemblyThe following diagra
ODU Installation RCF6001 Satellite TerminalPage 5-24 TM082 - Rev. 1.0Figure 4-4 Typical 10-Watt / 20-Watt Mounting382Step 3654Step 17654Step 271BU
RCF6001 Satellite Terminal ODU InstallationTM082 - Rev. 1.0 Page 5-25 Interface Connections for the High Power C-Band ODU AssembliesThe following des
ODU Installation RCF6001 Satellite TerminalPage 5-26 TM082 - Rev. 1.02. BUC / SSPA Interface PortFunction: Provides the serial interface for com
RCF6001 Satellite Terminal ODU InstallationTM082 - Rev. 1.0 Page 5-27
ODU Installation RCF6001 Satellite TerminalPage 5-28 TM082 - Rev. 1.0
Appendix ADMD2401 LB/ST Satellite Modem Technical SpecificationsA.1 IntroductionThis section defines the technical performance parameters and requirem
Operation RCF6001 Satellite TerminalPage 3-2 TM082 Rev. 1.0DMD2401 LB/ST Technical SpecificationsTransmit and Receive Data RatesDMD2401LB BPSK - 9.6
RCF6001 Satellite Terminal OperationTM082 Rev. 1.0 Page 3-3AlarmsSummary Alarms: Two separate form-C contactsavailable at the rear panel. Each provid
Operation RCF6001 Satellite TerminalPage 3-4 TM082 Rev. 1.0C-Band Block Upconverter SpecificationsElectrical Performance ParametersOutput frequency r
RCF6001 Satellite Terminal Table of ContentsTM082 - Rev. 1.0 iv
RCF6001 Satellite Terminal DescriptionTM082 - Rev. 1.0 Page 1-1Highlights• Complete C- or Ku-Band Satellite TerminalSystem• Optiona