SMS-451 Satellite Switch Model A, E, and T Installation and Operation Manual Part Number MN/SMS451. IOM Revision 0
SMS-451 Satellite Switch Revision 0 Preface MN/SMS451.IOM viii ELECTRICAL SAFETY The SMS-451 Satellite Switch has been shown to comply with the fo
SMS-451 Satellite Switch Revision 0 Preface MN/SMS451.IOM ix Installation The installation and connection to the line supply must be made in complia
SMS-451 Satellite Switch Revision 0 Preface MN/SMS451.IOM x EMC (Electromagnetic Compatibility) In accordance with European Directive 89/336/EEC,
SMS-451 Satellite Switch Revision 0 Preface MN/SMS451.IOM xi Warranty Policy This Comtech EF Data product is warranted against defects in material a
SMS-451 Satellite Switch Revision 0 Preface MN/SMS451.IOM xii This page is intentionally left blank.
1–1 Chapter 1. INTRODUCTION This manual describes the SMS-451 Satellite Switch (Model A, E, or T), referred to in this document as “the switch.” 1
SMS-451 Sateliite Switch Revision 0 Introduction MN/SMS451.IOM 1–2 The switch contains: • Circuitry for the data • IF switching • Remote and loca
SMS-451 Sateliite Switch Revision 0 Introduction MN/SMS451.IOM 1–3 The system block diagram (Figure 1-2) shows how the switch provides the inter
SMS-451 Sateliite Switch Revision 0 Introduction MN/SMS451.IOM 1–4 A block diagram of the switch is shown in Figure 1-3. CONTROLLOGICFRONT PANELFAU
SMS-451 Sateliite Switch Revision 0 Introduction MN/SMS451.IOM 1–5 1.1.2 SMS-451E Description MANUALAUTOON-LINE FAULTMODULATORAAABBBMANUALAUTO
SMS-451 Sateliite Switch Revision 0 Introduction MN/SMS451.IOM 1–6 The system block diagram (Figure 1-5) shows how the switch provides the interface
SMS-451 Sateliite Switch Revision 0 Introduction MN/SMS451.IOM 1–7 Figure 1-6. SMS-451 Block Diagram with SDM-2020 Modulator and D
SMS-451 Sateliite Switch Revision 0 Introduction MN/SMS451.IOM 1–8 1.1.3 SMS-451T Description Note: The SMS-451T 1:1 ESC Protection Switch can only
SMS-451 Sateliite Switch Revision 0 Introduction MN/SMS451.IOM 1–9 J4J6J5J8J7J9J6J10POWERSUPPLYPOWERSUPPLYSMS-451TLOGIC CONTROLLOGIC/CONTROLRELA
SMS-451 Sateliite Switch Revision 0 Introduction MN/SMS451.IOM 1–10 1.2 Specifications The following specifications are referenced to the applicable
SMS-451 Sateliite Switch Revision 0 Introduction MN/SMS451.IOM 1–11 1.2.2 SMS-451E Specifications The interface operates to the specifications d
SMS-451 Sateliite Switch Revision 0 Introduction MN/SMS451.IOM 1–12 1.2.3 SMS-451T Specifications The interface operates to the specifications descr
2-1 Chapter 2. INSTALLATION This chapter provides system installation and external connection information. 2.1 Unpacking The switch and manual are
SMS-451 Satellite Switch Revision 0 Installation MN/SMS451.IOM 2-2 2.2 System Installation 2.2.1 SMS-451A Installation Install the switch as follows
SMS-451 Satellite Switch Revision 0 Installation MN/SMS451.IOM 2-3 2. Connect the “RX IF COM” BNC connector on the rear panel to the customer equip
SMS-451 Satellite Switch Model A, E, and T Installation and Operation Manual Part Number MN/SMS451.IOM Revision 0 May 1, 2003Comtech EF Data i
SMS-451 Satellite Switch Revision 0 Installation MN/SMS451.IOM 2-4 2.2.2 SMS-451E Installation Install the switch as follows: 1. Using four screws
SMS-451 Satellite Switch Revision 0 Installation MN/SMS451.IOM 2-5 2.2.3 SMS-451T Installation Install the switch as follows: 1. Mount the switch
SMS-451 Satellite Switch Revision 0 Installation MN/SMS451.IOM 2-6 2.3 External Connections 2.3.1 SMS-451A External Connections Connections betwee
SMS-451 Satellite Switch Revision 0 Installation MN/SMS451.IOM 2-7 2.3.1.1 Remote Interface (J5) The remote interface is provided on a 25-pin fema
SMS-451 Satellite Switch Revision 0 Installation MN/SMS451.IOM 2-8 2.3.1.2 Modem Fault A and B (J8, J9) The modem fault is provided on a 9-pin fema
SMS-451 Satellite Switch Revision 0 Installation MN/SMS451.IOM 2-9 2.3.1.5 Receive Data (J10, J12, J15) The RX Data output of the prime modem conn
SMS-451 Satellite Switch Revision 0 Installation MN/SMS451.IOM 2-10 2.3.2 SMS-451E External Connections Connections between the switch and other eq
SMS-451 Satellite Switch Revision 0 Installation MN/SMS451.IOM 2-11 2.3.2.1 ECL Baseband DATA I/O (B, Common, and A) The ECL interface is provided
SMS-451 Satellite Switch Revision 0 Installation MN/SMS451.IOM 2-12 Signal Function Name Pin # BACKWARD ALARM 1 IN BWI1 12 (See Note 2) BACKWAR
SMS-451 Satellite Switch Revision 0 Installation MN/SMS451.IOM 2-13 2.3.2.2 Remote Connector The Remote interface is provided on a 25-pin female D
Customer Support Contact the Comtech EF Data Customer Support Department for: • Product support • Information on returning/upgrading a product
SMS-451 Satellite Switch Revision 0 Installation MN/SMS451.IOM 2-14 2.3.2.3 Demodulator IF Inputs (B, RX IF, and A) These connectors are the RX IF
SMS-451 Satellite Switch Revision 0 Installation MN/SMS451.IOM 2-15 2.3.3 SMS-451T External Connections Connections between the switch and other e
SMS-451 Satellite Switch Revision 0 Installation MN/SMS451.IOM 2-16 2.3.3.1 ESC “A” Connector Pin Assignments (J16 and J26) The ESC prime interfac
SMS-451 Satellite Switch Revision 0 Installation MN/SMS451.IOM 2-17 2.3.3.2 ESC “B” Connector Pin Assignments (J17 and J27) The ESC backup interfa
SMS-451 Satellite Switch Revision 0 Installation MN/SMS451.IOM 2-18 2.3.3.3 ESC “COMMON” Connector Pin Assignments (J18 and J28) The ESC “2” common
SMS-451 Satellite Switch Revision 0 Installation MN/SMS451.IOM 2-19 2.3.3.4 Remote Interface OUT (J5 and J25) The Remote Interface is provided on a
SMS-451 Satellite Switch Revision 0 Installation MN/SMS451.IOM 2-20 This page is intentionally left blank.
3-1 Chapter 3. OPERATION This chapter provides operation procedures for the switch. 3.1 Overview Note: In the event of power loss to the switch (F
SMS-451 Satellite Switch Revision 0 Operation MN/SMS451.IOM 3-2 3.2 SMS-451A/E Front Panel The front panel ( Figure 3-1) has indicators to show t
SMS-451 Satellite Switch Revision 0 Operation MN/SMS451.IOM 3-3 3.3 SMS-451A/E Local Control Note: All local controls are located on the front
Table of Contents CHAPTER 1. INTRODUCTION... 1–1 1.1 Description.
SMS-451 Satellite Switch Revision 0 Operation MN/SMS451.IOM 3-4 3.3.2 SMS-451A/E Demodulator Operation To operate the switch from the front pane
SMS-451 Satellite Switch Revision 0 Operation MN/SMS451.IOM 3-5 3.5 SMS-451T Front Panel IMPORTANT Operation of the switch is controlled by th
SMS-451 Satellite Switch Revision 0 Operation MN/SMS451.IOM 3-6 This page is intentionally left blank.
A–1 Appendix A. B-141-1 INTERFACE BREAKOUT PANEL This appendix provides a description and external connections of the breakout panel used with the
SMS-451T 1:1 ESC Protection Switch Revision 0 B-141-1 Interface Breakout Panel MN/SMS451.IOM A–2 Connections between the breakout panel and other eq
SMS-451T 1:1 ESC Protection Switch Revision 0 B-141-1 Interface Breakout Panel MN/SMS451.IOM A–3 A.2 External Connections A.2.1 ESC-1 Interface
SMS-451T 1:1 ESC Protection Switch Revision 0 B-141-1 Interface Breakout Panel MN/SMS451.IOM A–4 Refer to Figure A-2 for the schematic diagram of th
SMS-451T 1:1 ESC Protection Switch Revision 0 B-141-1 Interface Breakout Panel MN/SMS451.IOM A–5 A.2.2 8 kbps RS-422 Interface (P2) The 8 kbps R
SMS-451T 1:1 ESC Protection Switch Revision 0 B-141-1 Interface Breakout Panel MN/SMS451.IOM A–6 A.2.4 Backward Alarm (TB2) The backward alarm outp
i-1Index A AC Power (J34, J24), 2-9 AC Power (J2 and J24), 2-19 ADPCM Audio Connector (TB3), A-6 Alarm outputs (TB1), A-5 B B-141-1 Breakout Panel,
SMS-451 Satellite Switch Revision 0 Preface MN/SMS451.IOM iv 2.3.3 SMS-45T External Connections ...
SMS-451 Satellite Switch Revision 0 Index MN/SMS451.IOM i-2 T Transmit Clock (J2, J4, J7), 2-9 Transmit Data (J1, J3, J6), 2-9 Transmit IF Connecto
METRIC CONVERSIONS Units of Length Unit Centimeter Inch Foot Yard Mile Meter Kilometer Millimeter 1 centimeter — 0.3937 0.03281
2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 • 333 • 2200 PHONE 480 • 333 • 2161 FAX
SMS-451 Satellite Switch Revision 0 Preface MN/SMS451.IOM v Figures Figure 1-1. SMS-451A ...
Preface About this Manual This manual describes the installation and operation information for the Comtech EF Data: • SMS-451A 1:1 Satellite Mode
SMS-451 Satellite Switch Revision 0 Preface MN/SMS451.IOM vii Metric Conversion Metric conversion information is located on the inside back cover of