CDM-840 Remote Router Revision 0
Ethernet Management MN-CDM840
5–37
Click [Submit] once the desired changes have been made to these items.
Set Time (hh:mm:ss) – Enter a time using HH:MM:SS format (where HH = hour [00 to 23],
MM = minutes [00 to 59], and SS = seconds [00 to 59]).
Set Date (dd/mm/yy) – Enter a date using the European time format DD/MM/YY (where
DD = day [01 to 31], MM = month [01 to 12], and YY = year [00 to 99]).
Click [Submit] once the desired changes have been made to these items.
Circuit ID – Enter a Circuit ID string consisting of 4 to 24 characters. Once the desired string
had been entered in this section, click [Submit] as needed to save this change.
(FUTURE) Warm Up DelayThis selection is not operable in this initial product release.
(FUTURE) Warm Up Countdown – This selection is not operable in this initial product release.
(FUTURE) G.703 Clock Extended ModeThis selection is not operable in this initial product
release.
Adjustment for Internal 10 MHz High Stability Reference – Enter a value from -999 to
(+)999, then click [Submit] to save this change.
Test Mode – Use the drop-down menu to select test mode as follows:
Normal Mode – This mode clears any test modes or loopbacks, and places the unit back
into an operational state.
Tx CW – This test mode forces the modulator to transmit a pure carrier (unmodulated).
Tx Alt 1/0 – This test mode forces the modulator to transmit a carrier modulated with an
alternating 1,0,1,0 pattern, at the currently selected symbol rate. This causes two discrete
spectral lines to appear, spaced at +/- half the symbol rate, about the carrier frequency. This
mode is used to check the carrier suppression of the modulator.
Click [Submit] once the desired Test Mode has been selected.
Save/Load Configuration
This section allows the user to save, then load (recall) up to 10 configuration sets.
To save a configuration set: After all configuration parameters have been adjusted to suit, use the
top (Save) Select Location dropdown to select 1 through 10, then click [Save Configuration] as
needed to store the specified configuration settings.
To load (recall) a configuration set: Use the bottom (Load) Select Location dropdown to select 1
through 10, then click [Load Configuration] as needed to recall the selected configuration
settings.
(FUTURE) Redundancy
This section is not operable in this initial product release.
BERT Config
(Where BERT is the acronym for Bit Error Rate Test) Using the drop-down menus:
Configure the Tx or Rx BERT State as On or Off.
Configure the Tx or Rx BERT Pattern as 2^23-1 (2
23
-1) or 2047.
Set Error Insertion as either Off or 10E-3.