LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter MN-LPOD
System Connections, Installation and Startup Revision 10
2–9
PS 1 / PS 1.5 J10 (left), J11 (right)
PS 2 J10 (left), J11 (right)
2.3.6 Connector ‘J9 | OUTPUT SAMPLE’ (PS 2 Only)
The ‘J9 | OUTPUT SAMPLE’ port is a Type ‘N’ female connector
available only on the PS 2 model. It provides a nominal -40 dB
sample of the output signal. A calibration label is provided near
the connector that shows the actual coupling values vs.
frequency.
2.3.7 Connectors ‘J10 | MODEM Rx’ and ‘J11 | LNB’ (Optional Interfaces)
The ‘J10 | MODEM Rx’ and J11 | LNB ports are
both Type ‘N’ female connectors, providing both bias
and a reference signal to a Low Noise Block
Converter (LNB), and passing the LNB’s L-Band
output to the modem’s Rx input.
2.3.8 Ground Connector
A #10-32 stud is provided at the locations shown in Figure 2-6 for connecting a
common chassis ground among equipment.
Figure 2-6. LPOD Ground Connectors