Comtech EF Data CDM-710L Spécifications Page 237

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 252
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 236
CDM-710 Broadcast Satellite Modem Revision 10
Remote Control MN/CDM710.IOM
A–75
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response
to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Redundancy
State
RED= 1 byte Command or Query.
Unit returns the redundancy state of the unit, where:
0 = Offline
1 = Online
*** This command can be used to force the unit offline, this is
done by sending RED=0. This is only valid if redundancy mode
is enabled. If redundancy is not enabled, then RED=0 will return
an error. The unit cannot be forced online.
*** If the unit is not in redundancy mode, then the unit will
always be online.
Example: RED=0 (force unit offline)
RED=
RED?
RED*
RED#
RED? RED=x
(see description of
arguments)
Vue de la page 236