CDD-880 Multi Receiver Router Revision 1
Ethernet-based Remote Product Management MN-CDD880
5–22
Rx Spectrum Invert Use the dropdown menu to select Spectrum Inversion operation as
eitherNormalorInverted.
RxDescramUsethedro pdownmenutoselectRxDescramblingaseitherOfforNormal.
Eb/No Al arm Pt (0.116.0) Enter the Eb/No Alarm Point value, in dB. This value, as
calcula
ted by the demodulator, is the energy per bit (Eb) divided by the noise spectral
density(No).
When ACM is enabled, the CDD880 will issue an alarm only if the
demodulatorisatthelowestavailableMODCOD(BPSK).
Circuit ID (424) Enter an identification label for the demod, from four to 24 characters.
Click[Submit]tosave.
AcquisitionRange(1200)Ent
ertheAcquisitionRangevalue,inkHz.Notethattherangeis
dependentonthecurrentsymbolrateofthedemodulator.Click[Submit]tosave.