CDM-800 Gateway Router Revision 1
Rear Panel Connections MN-CDM800
3–12
3.3.2.2 AC Operation – Replacing Fuses
FOR CONTINUED OPERATOR SAFETY, ALWAYS REPLACE THE FUSES WITH THE
CORRECTTYPEANDRATING.
TheCDM800usestwo20mmSlowblowfusesoneeachforlineand neutralconnections.The
fusesarelocatedintherearpanelatthepowersupply(Figure37).
DISCONNECTTHEPOWERSUPPLYBEFOREPROCEEDING!
The fuses are contained within a fuse holder that is pressfit into the body of the IEC power
module.
Figure 3-7. Replacing CDM-800 AC Fuses
Toreplacethefuses:
First,unseatthefuseholderfromtheIECpowermodule.
o Usetheslot
toprythehol
d
eroutwardfromtheIECpowermodule.
o Pulltheholderstraightout, andthenswingtheholderawayfromthemodule.
Then,removeandreplacethefusesasneeded.
o UseT2.5A(2.5Amp)fusesforstandardoperation.
o UseT4.5A(4.5Amp)fuseswhena Block Upconverter(B
UC)isinstalled.
Finally,reseatthefuseholderintheIECpowermodule.