CDM-840 Remote Router Revision 2
Ethernet-based Remote Product Management MN-CDM840
6–47
• BUC Low or High Current Limit (0 to 4000) – Enter the BUC current alarm for either limit in
100mA increments.
Set the desired BUC configurations. Click [Submit BUC Control] to save.
BUC Status
BUC Power Supply, BUC Voltage (V), and BUC Current (mA) – When the presence of BUC Power
Supply is detected, it is acknowledged here and its voltage and current information is
continuously monitored and is provided on a read-only basis.
Click [Refresh] to update this section with its latest available statistics.
6.4.4.5.2.7 Configuration | WAN | LNB (Low Noise Block Downconverter)
This page is operational only when an optional LOW-
NOISE BLOCK
DOWNCONVERTER is installed.
Use this page to configure Low-Noise Block Downconverter parameters, and to display the LNB
status for L-Band operation.
Figure 6-22. Configuration | WAN | LNB Page
LNB Control
The acceptable/valid operating range for each item in this section is provided in parentheses.
• LNB DC Power – Use the drop-down list to select the power as Off, 13V, 18V, or 24V.