CDD-562L/564 Demodulator with IP Module Revision 2
CDD-56X CLI and Telnet Operation MN/CDD564L.IOM
8–9
8.2.2.3 Feature Configuration page
Chapter 1. INTRODUCTION
Appendix A. FAST ACTIVATION PROCEDURE
Access the Feature Configuration from the Administration page to display the current availability
for each feature. Any feature marked “Unavailable” is a FAST feature that must be activated with
a FAST Option Purchase Access Code.
This page contains the following unique selections/fields:
Selection Entry Description
Ping Reply P Toggles [Enabled] or [Disabled]:
Enabled tells the demodulator to respond to ping requests
directed to the demodulator Ethernet Interface.
Disabled tells the demodulator not to respond to ping
requests. This is used as a security feature to prevent
unauthorized parities from determining if a device exists via
the ping utility.
Telnet E Toggles [Enabled] or [Disabled]:
Enabled allows access via Telnet.
Disabled denies access via Telnet.
SNMP N Toggles [Enabled] or [Disabled]:
Enabled tells the demodulator to respond to SNMP requests
against the private and public MIB.
Disabled tells the demodulator not to respond to SNMP
requests against the private and public MIB.