Entry Channel Mode Switching
B-32 Vipersat CDM-570/570L User Guide
Figure B-19
Entry Channel Mode v2 Configuration, Hub
Remote Configuration
The demodulator (receive) configuration of each Remote in the group must be
set appropriately in order to receive the TAP from the Hub. Because the TAP
provides the necessary transmit parameters for the Remotes, manual modulator
configuration by the operator is unnecessary. The Entry Channel configuration
of the Remote (figure B-20) must include:
ECMv2 Mode (Online, Wait, Offline)
Group ID
TAP IP Multicast Address
BUC LO Frequency