Comtech EF Data MBT-4000B Spécifications Page 69

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 88
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 68
MBT-4000B Multi-band Transceiver System Revision 1
Serial-based Remote Product Management MN/MBT4000B.IOM
6–17
Parameter
Type
Command
(Instruction Code
and qualifier)
Valid on
MBT or
BUC/BDC
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes i.e., ASCII codes
between 48 and 57)
Response to Command
(Target to Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Retrieve
Alarm Status
N/A
All
92 bytes (MBT),
74 bytes (BDC),
64 bytes (BUC),
alphanumeric
Query only.
Returns the Query the Alarm status of the unit
Example for MBT-4000B base:
<0001/RAS?{cr}
>0001/RAS={cr}
15VT1=OK{cr}
7V5T1=OK{cr}
5VLT1=OK{cr}
28VT1=OK{cr}
REFLD=OK{cr}
IICST=OK{cr}
LNAC1=OK{cr} (Note 2)
LNAC2=OK{cr} (Note 2)
LNAW1=OK{cr} (Note 3)
LNAW2=OK{cr} (Note 3)
LNAI1=OK{cr} (Note 4)
LNAI2=OK{cr}{lf} (Note 5)
Example for BUC/BDC:
<0001A1/RAS?{cr}
>0001A1/RAS={cr}
15VLT=OK{cr}
7V5LT=OK{cr}
5VOLT=OK{cr}
REFLD=XX {cr} (reserved for future use)
SYNLD=OK{cr}
HSTMP=OK{cr}
LNACR=OK{cr}{lf} (Note 1)
Notes:
1. LNACR will only appear for BDC.
2. FT reported if MAX current exceeded.
3. FT reported if LCW window current exceeded.
4. FT reported if EAM = 11 & Pin F of J9 High.
5. FT reported if EAM = 21 & Pin F of J8 High, not applicable to
MBT-4000B.
N/A
RAS?
RAS=x….x
(see Description of
Arguments for
details)
Vue de la page 68
1 2 ... 64 65 66 67 68 69 70 71 72 73 74 ... 87 88

Commentaires sur ces manuels

Pas de commentaire