UT-4500-A Series Upconverters Revision 1
Rear Panel Connectors MN-UT4500A
3–10
3.3.1 Cable Connections – Standalone (Non-Redundant) Operation
In non-redundant (also referred to as standalone or single thread) upconverter configurations
the upconverter has an Input/Output Module (IOM-XX) for the RF Input and the IF Output. An
upconverter with a Transmit Switch Module (TSM-XX) may be operated in a non-redundant
configuration if an IOM is unavailable.
Figure 3-4 shows a non-redundant configuration using with an IOM installed; Figure 3-5 shows
cabling accomplished with a TSM installed.
Figure 3-4. Standalone (Non-Redundant) Upconverter Configuration
Figure 3-5. Standalone (Non-Redundant) Upconverter Configuration with Transmit Switch
Module (TSM-XX)