Comtech EF Data KST-2000A Spécifications Page 49

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 182
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 48
3–1
Chapter 3. OPERATION
This chapter provides the following information: Initial setup (single-thread system),
initial setup (redundant system), RJU-2000 Redundant Junction Unit description, 1:1 re-
dundant KST-2000A/B system operation, Up converter description, and Down converter
description.
3.1 Initial Setup (Single-Thread System)
This section details the procedures necessary to laboratory test a single-thread
KST-2000A/B system for the first time. Refer to Figure 3-1 for system setup.
Note: Ensure that the termination selected for the HPA output is sized to handle the
HPA output power.
1. Apply power to the KST-2000A/B.
2. After a few seconds ensure that the GREEN TX ON LED is flashing, and the
fault LED is extinguished. Refer to Section 4 if this is not the case.
3. Using a KP-10 or PC equipped with a terminal or Windows based M&C pro-
gram, ensure communication is available to the system M&C, via J2, remote
connector. (Refer to M&C software manual, P/N MN/M&CWIN.IOM)
Default Communication Parameters Address 1
Baud Rate 9600
Parity Even
Stop bits 2
Data length 7 bits
Vue de la page 48
1 2 ... 44 45 46 47 48 49 50 51 52 53 54 ... 181 182

Commentaires sur ces manuels

Pas de commentaire