Comtech-ef-data CRS-400 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Comtech-ef-data CRS-400. Comtech EF Data CRS-400 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 96
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Part Number
MN/CRS400.IOM
Revision 0
CRS-400
1:8 Redundancy Switch
Installation and O
p
eration Manual
Vue de la page 0
1 2 3 4 5 6 ... 95 96

Résumé du contenu

Page 1 - CRS-400

Part Number MN/CRS400.IOM Revision 0 CRS-400 1:8 Redundancy Switch Installation and Operation Manual

Page 2

CRS-400 1:8 Redundancy Switch Revision 0 Preface MN/CRS400.IOM vi A.5.4 (MONITOR) COMM-STATE (Communications)...

Page 3 - Errata A

CRS-400 1:8 Redundancy Switch Revision 0 Preface MN/CRS400.IOM vii Figures Figure 1-1 CRS-400 Block Diagram with Modems and CRS-280 IF Switch...

Page 4

CRS-400 1:8 Redundancy Switch Revision 0 Preface MN/CRS400.IOM viii ABOUT THIS MANUAL This manual provides installation and operation information fo

Page 5

CRS-400 1:8 Redundancy Switch Revision 0 Preface MN/CRS400.IOM ix RECOMMENDED STANDARD DESIGNATIONS Recommended Standard (RS) Designations have been

Page 6 - USTOMER

CRS-400 1:8 Redundancy Switch Revision 0 Preface MN/CRS400.IOM x EMC COMPLIANCE This is a Class A product. In a domestic environment, it may cause r

Page 7 - Table of Contents

CRS-400 1:8 Redundancy Switch Revision 0 Preface MN/CRS400.IOM xi SAFETY COMPLIANCE EN 60950 Applicable testing is routinely performed as a conditi

Page 8

CRS-400 1:8 Redundancy Switch Revision 0 Preface MN/CRS400.IOM xii WARRANTY POLICY This Comtech EF Data product is warranted against defects in mate

Page 9

1 Chapter 1. Introduction CRS-400 1:8 Redundancy Switch Optional CRS-280 IF Switch 1.1 DESCRIPTION The Comtech EF Data CRS-400 1:8 Redundancy

Page 10 - Preface MN/CRS400.IOM

CRS-400 1:8 Redundancy Switch Revision 0 Introduction MN/CRS400.IOM 2 The CRS-400 is fully modular in construction. All replaceable modules insert i

Page 11 - Figures

CRS-400 1:8 Redundancy Switch Revision 0 Introduction MN/CRS400.IOM 3 There are several other key operational features of the CRS-400 architecture:

Page 13

CRS-400 1:8 Redundancy Switch Revision 0 Introduction MN/CRS400.IOM 4 Figure 1-3 depicts the separate Tx and Rx sections of the optional IF switch.

Page 14 - EN50082-1 C

CRS-400 1:8 Redundancy Switch Revision 0 Introduction MN/CRS400.IOM 5 1.2 FRONT AND REAR PANELS The front panel contains the Vacuum Fluorescent Dis

Page 15 - OMPLIANCE

CRS-400 1:8 Redundancy Switch Revision 0 Introduction MN/CRS400.IOM 6 1.3 MAJOR ASSEMBLIES AND OPTIONS Part Number Description Model # Comments

Page 16 - ARRANTY

CRS-400 1:8 Redundancy Switch Revision 0 Introduction MN/CRS400.IOM 7 1.4 SPECIFICATIONS (PRELIMINARY) Characteristic Requirement AC Prime Power T

Page 17 - Chapter 1. Introduction

CRS-400 1:8 Redundancy Switch Revision 0 Introduction MN/CRS400.IOM 8 1.4.1 DATA REDUNDANCY AND CONTROLLER Characteristic Requirement Number of Pri

Page 18 - Introduction MN/CRS400.IOM

CRS-400 1:8 Redundancy Switch Revision 0 Introduction MN/CRS400.IOM 9 1.4.2 CRS-280 IF REDUNDANCY SWITCH SPECIFICATIONS Characteristic Requirement

Page 19

CRS-400 1:8 Redundancy Switch Revision 0 Introduction MN/CRS400.IOM 10 1.4.3 OUTLINE DRAWING Dimensions are shown in both inches and (centimeters)

Page 20

11 Chapter 2. Installation and Initial Setup Unpacking and Inspection Front Panel Rear Panel Mounting Instructions Installation Details Cables and Co

Page 21

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 12 Figure 2-1 CRS-400 Front Panel Figure 2-2 CRS-400 Rear Pane

Page 22 - SSEMBLIES

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 13 2.1 UNPACKING AND INSPECTION 1 Inspect shipping containers for dama

Page 23 - RELIMINARY

s:\tpubs\manuals\released_word\switches\crs400_rev0\errataa.doc 1 Errata A Comtech EF Data Documentation Update Subject: Changes to Related Document

Page 24 - ONTROLLER

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 14 2.3.1 DATA CONNECTORS The Data connectors on the TMI plug-ins lead

Page 25 - 1.4.2 CRS-280 IF R

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 15 CAUTION Do not allow the internal rack temperature to exceed 50o C.

Page 26

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 16 2.6.2 TMI DATA CONNECTOR (HSSI) Table 2-1 describes the pinout for

Page 27

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 17 HSSI/EIA-613 Interface Connector Pinout -- J6 / J7 To modem J5 To

Page 28

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 18 2.6.3 SYSTEM ALARMS CONNECTOR Located on the System Controller card

Page 29

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 19 Pin Description 16 BU Demod Replaces Traffic Demod “N”, Bit 2 of

Page 30 - NSTRUCTIONS

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 20 Pin # Condition 10, 22 +5V input 12, 24 +12V input 11, 13 Groun

Page 31 - ONNECTORS

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 21 2.6.6 AUXILIARY SERIAL CONNECTOR / PASS-THROUGH This connector is u

Page 32 - 2.6.2 TMI D

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 22 2.7 TMI MODULES The following paragraphs describe settings for any

Page 33 - (Note 1)

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 23 Table 2-6 HSSI TMI Jumper Selection (TA/CA) TA/CA Selection J1 Jum

Page 35 - 2.6.4 IF S

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 24 2.8 RMI MODULES The following paragraphs describe settings for any

Page 36

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 25 Table 2-8 HSSI RMI Jumper Selection TA/CA Selection J1 Jumpers De

Page 37 - UXILIARY

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 26 2.9 CONNECTING THE CABLES WARNING Ensure that all power to the equ

Page 38 - 2.7 TMI M

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 27 2.10 CONFIGURING THE MODS/DEMODS – FIRMWARE VERSIONS For correct op

Page 39

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 28 2.11 APPLYING POWER TO THE SWITCH Note: Each CRS-400 is shipped w

Page 40 - 2.8 RMI M

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 29 2.12 CONFIGURING THE SWITCH The unit was shipped with the following

Page 41

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 30 Notes: Use the INFO and MONITOR menus to view the status of the mo

Page 42 - 2.9.1 HSSI C

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 31 2.13.2 CONFIGURING AND CABLING FOR MULTIPLE TRANSPONDERS, USING TH

Page 43 - IRMWARE

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 32 2.14 CONFIGURING AUTOMATIC OPERATION MODE After the IF cabling is f

Page 44 - OWER TO THE

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 33 2.14.3 125 2.14.4 RESTORE HOLDOFF OPERATION The “Restore Holdoff” s

Page 45

Copyright © Comtech EF Data, 2001. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, (480) 333

Page 46

CRS-400 1:8 Redundancy Switch Revision 0 Installation and Setup MN/CRS400.IOM 34

Page 47

35 Chapter 3. Operation Front Panel Display Front Panel Keys LED Indicators Menu Trees Flash Upgrading 35 37 38 39 42 3.1 FRONT PANEL DISPLAY Users

Page 48 - PERATION

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 36 Where this solid block cursor would obscure the item being edited (for exa

Page 49

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 37 3.2 FRONT PANEL KEYS The keypad contains six individual key switches mount

Page 50

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 38 3.3 LED INDICATORS Table 3-1 describes the three LEDs at the top left of t

Page 51 - Chapter 3. Operation

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 39 3.4 MENU TREES Nested menus display all available options and prompt users

Page 52

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 40 Figure 3-1 Principle Menus Tree for Independent Mode CRS-400 Menu TreeSWI

Page 53 - IMPORTANT

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 41 Figure 3-2 Principle Menus Tree for Dependent Mode CRS-400 Menu TreeSWIT

Page 54 - 3.3 LED I

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 42 3.5 FLASH UPGRADING The CRS-400 uses “flash memory” technology internally,

Page 55

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 43 Appendix A. FRONT PANEL OPERATION DETAILS OPENING SCREEN SELECT CONFIG INF

Page 56 - CRS-400 Menu Tree

CUSTOMER SUPPORT Contact the Comtech EF Data Customer Support Department for:  Product support or training  Information on upgrading or returning

Page 57

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 44 A.3 CONFIG CONFIG: MANUAL AUTO[OFF] ACTIVE REMCONT OPTIONS The sub-br

Page 58 - PGRADING

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 45 A.3.2 (CONFIG) AUTO[OFF OR ON] OPERATING MODE: AUTO-OFF AUTO-ON (ENTER)

Page 59 - DETAILS

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 46 A.3.4.2 (CONFIG, REM CONTROL) SETTINGS REMOTE CONTROL: FORMAT BAUD TYPE

Page 60 - A.3 CONFIG

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 47 A.3.4.2.3.1 (CONFIG, REM, SETTINGS, TYPE) RS232 IN RS232 MODE THE BUS AD

Page 61

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 48 Masking faults will prevent the switch from performing Auto mode functions

Page 62

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 49 A.3.5.3 (CONFIG, OPTS) HOLDOFFS BACKUP HOLDOFF SEC: 05 RESTORE HOLDOFF S

Page 63 - A.3.5.1 (CONFIG, OPTS) MASKS

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 50 A.3.5.4 (CONFIG, OPTS) RESTORE-TIME RESTORE TIME: [OFF] OFF/ON SET-TIME

Page 64

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 51 A.4 INFO (INFORMATION) INFO: SWITCH-ID SETUP IF-SWITCH REMCONT MASK

Page 65 - RESTORE HOLDOFF SEC: 10

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 52 A.4.4 (INFO) REMCONT (REMOTE CONTROL INFO) REM CNTL: REMOTE RS485-4W AD

Page 66

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 53 A.5 MONITOR MONITOR: STATUS SW-ALARM STORED-EVENTS COMM-STATE Select a

Page 67 - A.4 INFO (I

iii Table of Contents Customer Support...

Page 68 - MOD DMD Å PSU-A PSU-B Æ

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 54 A.5.3 (MONITOR) STORED EVENTS STORED EVENTS: VIEW CLEAR-ALL (PRESS ENTE

Page 69 - A.5 MONITOR

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 55 A.6 STORE/LD (STORE OR LOAD CONFIGURATION) STORE/LOAD CONFIG: STORE LOAD

Page 70 - A.5.4 (MONITOR) COMM-STATE (C

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 56 A.6.2 (STORE/LD) LOAD LOAD CONFIGURATION FROM LOCATION: 10 (ENTER) Se

Page 71 - A.6 STORE/LD (S

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 57 A.7 UTIL (UTILITY) UTILITY: CLOCK SWITCH-ID DISPLAY POLLING (ENTER)

Page 72 - A.6.2 (STORE/LD) LOAD

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 58 A.7.3 (UTILITY) DISPLAY (DISPLAY BRIGHTNESS) EDIT DISPLAY BRIGHTNESS: 10

Page 73 - A.7 UTIL (U

59 Appendix B. REMOTE CONTROL Introduction EIA-485 EIA-232 Basic Protocol Packet Structure Remote Control Commands 59 59 60 60 61 66 B.1 INTRODUCTIO

Page 74 - A.7.4 (UTILITY) POLLING

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 60 In the other direction, on the other pair, each target has a tri-stateable

Page 75 - Appendix B. REMOTE CONTROL

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 61 All data is transmitted in framed packets. The controller is assumed to be

Page 76 - B.3 EIA-232

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 62 Target-to-controller: Start of Packet Target Address Address Delimiter In

Page 77 - TRUCTURE

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 63 Remote monitor and control of units attached to the Switch is available, t

Page 78

CRS-400 1:8 Redundancy Switch Revision 0 Preface MN/CRS400.IOM iv CHAPTER 2. INSTALLATION AND INITIAL SETUP...

Page 79 - UALIFIER

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 64 2) From Target to Controller, the only permitted values are: = (ASCII cod

Page 80

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control MN/CRS400.IOM 65 The ! code (target to controller) is only used as follows: If the controll

Page 81 - RGUMENTS

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control

Page 82

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control

Page 83

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control

Page 84

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control

Page 85

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control

Page 86

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control

Page 87 - (use ADQ for detail)

CRS-400 1:8 Redundancy Switch Revision 0 Remote Control

Page 88

73 Appendix C. CABLE DRAWINGS Figure C-1 PC 9-Pin Serial Port to CRS-400 EIA-232 Remote Control Port Figure C-1 shows the cable required for a si

Page 89 - Appendix C. CABLE DRAWINGS

CRS-400 1:8 Redundancy Switch Revision 0 Preface MN/CRS400.IOM v 2.14 Configuring Automatic Operation Mode ...

Page 90 - Figure C-2 HSSI Data Cable

CRS-400 1:8 Redundancy Switch Re

Page 91

CRS-400 1:8 Redundancy Switch Re

Page 92

CRS-400 1:8 Redundancy Switch

Page 93

77 Index A About Rack Support, 15 About this Manual, viii Activate Desired Traffic Mods/Demods, 29 Address, 27 Alarm Masking, 33 Applying Power to t

Page 94

CRS-400 1:8 Redundancy Switch Revi

Page 95 - Units of Weight

METRIC CONVERSIONS Units of Length Unit Centimeter Inch Foot Yard Mile Meter Kilometer Millimeter 1 centimeter — 0.3937 0.03281

Page 96 - 480 • 333 • 2161

2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 • 333 • 2200 PHONE 480 • 333 • 2161 FAX

Commentaires sur ces manuels

Pas de commentaire