UT4500 Series Up Converter MN/UT4500.IOM
Remote Control Revision 2
77
5.7 ERROR PROCESSING
5.7.1 GENERAL ERRORS
The following Error Responses may be generated by any command instead of a
confirmation:
>DEV?COM CU CMD UNRECOGNIZED'cr''lf']
>DEV?COM IP INVALID PARAM'cr''lf']
>DEV?COM PE PARITY ERROR'cr''lf']
5.7.2 CONFIGURATION ERRORS
The following Error Responses may be generated by configuration commands:
>DEV?COM LO DEVICE IN LOCAL MODE'cr''lf']
5.7.3 MODE ERRORS
The following Error Responses may be generated by Mode selection:
>DEV?COM AE ONLY VALID WHEN BACKUP'cr''lf']
>DEV?COM OE OFFLINE NOT AVAILABLE'cr''lf']
>DEV?COM CN COMMAND NOT AVAILABLE'cr''lf']
5.7.4 TIME-OUTS
A time-out should be assumed if there is no response in 500 milliseconds. The station
monitor and control computer should try at least three times.