Comtech EF Data SDM-309B Spécifications Page 204

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 240
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 203
SDM-309B Satellite Modem Remote Control
MN/U-SDM309B Rev. # B-B–27
5.18 Bulk Consolidated Status Faults
This command causes all modem fault status to be returned. To reduce the length of the
response, fault status is embedded into the bit structure of the characters that are
returned. Faults are indicated by a binary 1 in the designated bit position.
Command:
<add/BCSF_”cr”
Response:
>add/BCSF_abcdefghij”cr””lf”]
Character “a”: Modulator fault status character 1.
Bit 6 = 1 always.
Bit 5 = Modulator fault.
Bit 4 = RF output status, actual not programmed status
(1 = on, 0 = off).
Bit 3 through Bit 0 = Binary representation (0 - 10) of the number of modulator
stored faults.
Character “b”: Modulator fault status character 2.
Bit 6 = 1 always.
Bit 5 = AGC fault.
Bit 4 = Modulator RF synthesizer fault.
Bit 3 = Bit clock fault.
Bit 2 = Transmit clock fault.
Bit 1 = I-channel fault.
Bit 0 = Q-channel fault.
Character “c”: Demodulator fault status character 1.
Bit 6 = 1 always.
Bit 5 = Demodulator fault.
Bit 4 = Carrier detect status (0 for decoder lock).
Bit 3 through Bit 0 = Binary representation (0 - 10) of the number of demodulator
stored faults.
Character “d”: Demodulator fault status character 2.
Bit 6 = 1 always.
Bit 5 = Demodulator RF synthesizer fault.
Bit 4 = not used.
Bit 3 = I-channel fault.
Bit 2 = Q-channel fault.
Bit 1 = Bit clock fault.
Bit 0 = BER threshold fault.
Character “e”: Common equipment fault status character 1.
Bit 6 = 1 always.
Bit 5 = M&C fault.
Bit 4 = Interface fault.
Vue de la page 203