Remote Control Operation SDM-650B Satellite Modem
B–8 Rev. 6
B.1.3.7.2 Select Modulator Rate
Command: <add/SMRx_”cr”
Response: >add/SMRx_”cr”
RF_OFF”cr””lf”]
Status Only: (See MR command.)
Where: x = A, B, C, or D (Filter designator).
Notes:
1. Setting the modulator turns OFF the RF transmitter.
2. If the modem is commanded to a filter (rate) which is not assigned (N/A), the
“error 2” message will be returned.
B.1.3.7.3 Select Modulator Rate Variable
Note: This command is only applicable for the variable rate option.
Command: <add/SMRV_nnn_mmmm.m”cr”
Response: >add/SMRV_nnn_mmmm.m”cr””lf”]
RF_OFF”cr””lf”]
Status Only: (See MR command.)
Where:
nnn = 1/2, 3/4, 7/8, or BP12 (Coder rate).
mmmm.m = 9.6 to 4080.0 (Data rate).
Note: Setting the modulator turns OFF the RF transmitter.