CDM-Qx Satellite Modem Revision 5
Front Panel Operation MN/CDMQx.IOM
5–51
(ConfigODULNBPower-On/Off) – LNB POWER- ON/OFF
If Power-On/Off is selected, the following sub-menu is displayed:
Select On or Off, using the arrow keys, then press ENT.
(ConfigODULNB10MHz) - LNB 10MHz
If 10MHz is selected, the following sub-menu is displayed:
Select On or Off, using the arrow keys, then press ENT.
(ConfigODULNBAlarm) - LNB ALARM
If Alarm is selected, the following sub-menu is displayed:
Select Upper or Lower, using the arrow keys, then press ENT.
If Upper is selected, the following sub-menu is displayed:
Edit the LNB Current Alarm Upper limit. This is accomplished by selecting the digit to
be edited, using the WXarrow keys. The value of the digit is then changed using the
STarrow keys. The user should then press ENT. The range of current is from 50 to 600
mA.
LNB Power:
On Off ( ENT)
LNB 10MHz Reference:
On Off ( ENT)
Set LNB Current Alarm
:
Upper Lower ( ENT)
LNB Current Alarm Upper
Limit: 200mA ( ENT)