SDM-300L3 Satellite Modem Revision 0
Front Panel Operation MN/SDM300L3.IOM
4–48
FUNCTION SELECT: CONFIGURATION: LOCAL AUPC:
TRACKING RATE (CONDITIONAL)
TRACKING RATE
5.0 dB/Min
IMPORTANT
Conditional: This menu is displayed when Local Modem AUPC = ON
located under the Utility: Modem Type menu.
Programs the maximum tracking rate of the AUPC.
Maximum tracking rate can range from 0.5 to 6.0 dBm/minute, in 0.5 dBm/minute steps.
FUNCTION SELECT: CONFIGURATION: LOCAL AUPC:
LOCAL CL ACTION (CONDITIONAL)
LOCAL CL ACTION
HOLD
IMPORTANT
Conditional: This menu is displayed when Local Modem AUPC = ON
located under the Utility: Modem Type menu.
Programs the Local Carrier Loss action (CL) for HOLD, NOMINAL, or MAXIMUM.
The modulator at the local carrier end moves to this value upon carrier loss.
HOLD Upon Carrier Loss (CL) the carrier level remains at the level just before carrier loss.
NOMINAL Upon CL the TX Carrier Level reverts to the Nominal Power Level programmed
under Configuration: Local AUPC: Nominal Power
MAXIMUM Upon CL the TX Carrier Level is programmed to the level programmed under
Configuration: Local AUPC: Maximum Power.