SDM-300L3 Satellite Modem Revision 0
Front Panel Operation MN/SDM300L3.IOM
4–100
FUNCTION SELECT: UTILITY: OUTDOOR UNIT:
ODU OUTPUT POWER (CONDITIONAL)
ODU OUTPUT POWER
OFF
IMPORTANT
Conditional: This menu is available only when ODU Power Supply, FSK,
and TX-IF Output are On.
Turns RF power at ODU/BUC On or Off. Select ODU Output Power On or Off.
Press [] or [] to select the ODU Output Power. Press [ENTER] to execute the change.
FUNCTION SELECT: UTILITY: OUTDOOR UNIT:
ODU PWR LEVELING (CONDITIONAL)
ODU PWR LEVELING
OFF
IMPORTANT
Conditional: This menu is available only when ODU Power Suppl
y
and TX-IF Output are On.
When Power Leveling is On the Modem TX-IF Output is continually adjusted to maintain the ODU
Power level set by selecting ODU PWR Leveling = On. In the On mode the modem Auto adjusts
the ODU Power Level. This requires an FSK capable ODU (BUC). The Monitor menu shows the
actual BUC Power and (T) Target Power. Press [] or [] to select the ODU Power Leveling.
Press [ENTER] to execute the change.