Vipersat Configuration
3-16 Vipersat CDD-56X Series User Guide
This value can be modified by entering a G at the command prompt to display
the dialog shown in figure 3-14 and entering a new value.
Figure 3-14
Slot Guardband prompt
Note: The value entered at the command line in figure 3-14 is in milliseconds.
The corresponding value expressed in bytes is calculated by the
CDD-56X based on the STDMA transmit bit rate as shown in the menu
in figure 3-7.
Slot Preamble Length
This menu item, which appears in all Hub configurations, displays the current
Slot Preamble size in milliseconds and bytes for the remotes in the group. The
Slot Preamble is the period between when the remote begins to transmit (sends
an ACK) to the Hub and when the first data packet is sent. This allows time for
signal lock to occur before data is sent, thus preventing data loss. Higher data
rates allow for a shorter preamble, since it is easier to achieve signal lock. The
setting for this parameter should be obtained using the Vipersat STDMA Calcu-
lator.
Note: When the BFAT feature is enabled, the preamble length is set automati-
cally for the unit.
Entering a P at the command prompt allows changing the preamble duration in
milliseconds.
Figure 3-15
Slot Preamble Length prompt
NOTE
NOTE