Comtech EF Data Vipersat 564L Guide de l'utilisateur Page 59

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 150
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 58
Chapter 3 - Using the Command Line Interface (CLI) 3-23
Vipersat Configuration
Figure 3-25
Entry Channel Switch Rates screen
Entering the Remote number at the command prompt in figure 3-25 allows the
SCPC Data Rate and the Switch Type for that Remote to be set, as shown in
figure 3-26. Switch type 0 corresponds to Load Switching; switch types 64
through 255 are user-defined, and must match VMS policies. When choosing
Load Switching as the Switch Type, the associated Remote must have the Load
Switching feature Enabled (see the section “STDMA/SCPC Automatic Switch-
ing” on page 3-29).
Figure 3-26
Remote SCPC Data Rate prompt
The Global SCPC Rate command can be used to set the data rate for all or a
majority of the Remotes. This allows the rate to be entered just once instead of
entering the rate for each Remote individually. Enter G at the command prompt
in figure 3-25.
Vue de la page 58
1 2 ... 54 55 56 57 58 59 60 61 62 63 64 ... 149 150

Commentaires sur ces manuels

Pas de commentaire