Vue de la page 214
CDM-600 Satellite Modem Revision 7
Remote Control MN/CDM600.IOM
16–27
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response
to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Configuration
Save
CST= 1 byte, value
of 0 thru 9
Command only.
Command causes the CDM600 to store the current
modem configuration in Configuration Memory location
defined by the one-byte argument (0 to 9).
Example: CST=4 (store the current configuration in
location 4)
CST=
CST?
CST*
CST#
N/A N/A
Configuration
Load
CLD= 1 byte, value
of 0 thru 9
Command only.
Causes the CDM600 to retrieve a previously stored
modem configuration from Configuration Memory
location defined by the one-byte argument (0 to 9).
Example: CLD=4 (load modem configuration from
location 4 to be the active configuration)
CLD=
CLD?
CLD*
CLD#
N/A N/A
ReCenter
Buffer
RCB= None Command only.
Forces the software to recenter the receive
Plesiochronous/Doppler buffer.
Note: This command takes no arguments.
Example: RCB=
RCB=
RCB?
RCB*
RCB#
N/A N/A
RTC Date DAY= 6 bytes Command or Query.
A date in the form ddmmyy (international format), where
dd = day of the month (01 to 31),
mm = month (01 to 12)
yy = year (00 to 99)
Example: DAY=240457 (April 24, 2057)
DAY=
DAY?
DAY*
DAY#
DAY? DAY=ddmmyy
(see description of
arguments)
RTC Time TIM= 6 bytes Command or Query.
A time in the form hhmmss, indicating the time from
midnight, where:
hh = hours (00 to 23)
mm = minutes (00 to 59)
ss = seconds (00 to 59)
Example: TIM=231259 (23 hours:12 minutes:59 seconds)
TIM=
TIM?
TIM*
TIM#
TIM? TIM=hhmmss
(see description of
arguments)