Comtech EF Data KST-2000B Spécifications Page 245

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 258
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 244
CDM-600 Satellite Modem Revision 7
ODU Operation MN/CDM600.IOM
D–9
D.2.13 (ODU,ENABLE,1:1,CSAT#1) MONITOR
(ODU,ENABLE,1:1,CSAT#2) MONITOR
(ODU,ENABLE,STANDALONE CSAT) MONITOR
MONITOR: TRANSMIT RECEIVE MISCELLANEOUS
POWER-SUPPLIES
Use the [] or [] keys to select the parameters to monitor, then press ENTER.
D.2.14 (ODU,ENABLE,1:1,CSAT#1, MONITOR) TX
(ODU,ENABLE,1:1,CSAT#2, MONITOR) TX
(ODU,ENABLE,STANDALONE CSAT, MONITOR) TX
TX: SYNTUNE = 09.6 VDC POWER = <24 dBm
IFLO = 11.1 VDC TEMP = 26 C
Press ENTER or CLEAR to return to previous menu.
D.2.15 (ODU,ENABLE,1:1,CSAT#1, MONITOR) RX
(ODU,ENABLE,1:1,CSAT#2, MONITOR) RX
(ODU,ENABLE,STANDALONE CSAT, MONITOR) RX
RX: SYNTUNE = 01.4 VDC
IFLO = 11.2 VDC TEMP = 26 C
Press ENTER or CLEAR to return to previous menu.
D.2.16 (ODU,ENABLE,1:1,CSAT#1, MONITOR) MISC
(ODU,ENABLE,1:1,CSAT#2, MONITOR) MISC
(ODU,ENABLE,STANDALONE CSAT, MONITOR) MISC
MISC: REF TUNE = 03.0 VDC
LNA = 00.05 mA FAN = 550 mA
Press ENTER or CLEAR to return to previous menu.
Vue de la page 244
1 2 ... 240 241 242 243 244 245 246 247 248 249 250 ... 257 258

Commentaires sur ces manuels

Pas de commentaire