IMPORTANT NOTE: The information contained in this document supersedes all previously published information regarding this product. Product spec
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Table of Contents Revision 1 viii Figure 1-8. SPOD PS 2 C-Band Dimensional Envelope ...
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–8 5.3.4.4 Instruction Code This is a three
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–9 ! (ASCII code 33) This character is used
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–10 5.1 Remote Commands and Queries Column
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–11 Parameter Type Command (Instruction Cod
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–12 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–13 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–14 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–15 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–16 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–17 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Table of Contents Revision 1 ix Figure A-18. KT-0000091 PS 2 C-Band 1:1 Redundancy Kit Exa
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–18 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–19 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–20 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–21 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–22 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–23 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–24 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–25 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–26 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–27 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Table of Contents Revision 1 x BLANK PAGE
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–28 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–29 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–30 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–31 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–32 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–33 Parameter Type Command (Instruction Code
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–34 Notes:
A–1 Appendix A. 1:1 REDUNDANCY A.1 SPOD Redundancy Operation Overview The SPOD Outdoor Amplifier / Block Up Converter can be used in a redundancy c
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–2 Figure A-1. Ethernet-based M&C using CEFD Kit KT-0000203 A.3.
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–3 A.3.2 Serial-based Monitor and Control The EIA-232 Interface is
xi PREFACE About this Manual This manual provides installation and operation information for the Comtech EF Data SPOD family of Outdoor Amplifiers. Th
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–4 The SPOD redundant mode does not specify which unit must be the ba
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–5 Only the offline unit is allowed to initiate a redundant switchove
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–6 • Type "CMD" (without the quotes) into the Run dialog b
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–7 A.5 1:1 Redundancy System Cabling and Installation Figure A-3 sho
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–8 Figure A-3. Typical SPOD 1:1 Redundancy System Cabling Schematic
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–9 A.6 Redundancy System Assembly Kit Examples Several kits are avail
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–10 A.6.1 SPOD PS 1 1:1 Redundancy Kit Examples Table A-1. Parts List
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–11 Figure A-4. KT-0000104 PS 1 C-Band 1:1 Redundancy Kit (Exploded V
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–12 Figure A-5. KT-0000104 PS 1 C-Band 1:1 Redundancy Kit (Assembled
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–13 BLANK PAGE
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Preface Revision 1 xii Conventions and References Patents and Trademarks See all of Comtech EF
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–14 Table A-2. Parts List for KT-0000090 PS 1 C-Band Coax Output 1:1 R
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–15 Figure A-6. KT-0000090 PS 1 C-Band Coax Output 1:1 Redundancy Kit
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–16 Figure A-7. KT-0000090 PS 1 C-Band Coax Output 1:1 Redundancy Kit
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–17 BLANK PAGE
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–18 Table A-3. Parts List for KT-0000089 PS 1 Ku-Band 1:1 Redundancy
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–19 Figure A-8. KT-0000089 PS 1 Ku-Band 1:1 Redundancy Kit Example (E
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–20 Figure A-9. KT-0000089 PS 1 Ku-Band 1:1 Redundancy Kit Example (A
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–21 BLANK PAGE
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–22 Table A-4. Parts List for KT-0000170 PS 1 X-Band 1:1 Redundancy K
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–23 Figure A-10. KT-0000170 PS 1 X-Band 1:1 Redundancy Kit Example (E
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Preface Revision 1 xiii Electrical Safety Notice CAUTION – Neutral Fusing: Double pole/neutra
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–24 Figure A-11. KT-0000170 PS 1 X-Band 1:1 Redundancy Kit (Assembled
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–25 BLANK PAGE
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–26 A.6.2 SPOD PS 1.5 1:1 Redundancy Kit Examples Table A-5. Parts Li
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–27 Figure A-12. KT-0020526 PS 1.5 C-Band DC Option 1:1 Redundancy K
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–28 Figure A-13. KT-0020526 PS 1.5 C-Band DC Option 1:1 Redundancy K
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–29 Figure A-14. KT-0020526 PS 1.5 C-Band DC Option 1:1 Redundancy Ki
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–30 Table A-6. Parts List for KT-0000060 PS 1.5 Ku-Band 1:1 Redundancy
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–31 Figure A-15. KT-0000060 PS 1.5 Ku-Band 1:1 Redundancy Kit Example
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–32 Figure A-16. KT-0000060 PS 1.5 Ku-Band 1:1 Redundancy Kit Example
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–33 BLANK PAGE
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Preface Revision 1 xiv Product Support For all product support, please call: +1.240.243.1880
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–34 A.6.3 SPOD PS 2 1:1 Redundancy Kits Table A-7. Parts List for KT-
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–35 Figure A-17. KT-0000091 PS 2 C-Band 1:1 Redundancy Kit Example (E
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–36 Figure A-18. KT-0000091 PS 2 C-Band 1:1 Redundancy Kit Example (
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–37 BLANK PAGE
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–38 Table A-8. Parts List for KT-0000254 PS 2 Ku-Band 1:1 Redundancy K
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–39 Figure A-19. KT-0000254 PS 2 Ku-Band 1:1 Redundancy Kit Example (
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–40 Figure A-20. KT-0000254 PS 2 Ku-Band 1:1 Redundancy Kit Example (
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–41 COMTECH EF DATA FREE STANDING UNISTRUT KIT (CEFD P/N KT-002
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–42 Figure A-22. PS 2 C-Band 1:1 Redundancy Free Standing Example Usi
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–43 Figure A-23. PS 2 C-Band 1:1 Redundancy Free Standing Example Usi
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Preface Revision 1 xv Limitations of Warranty The warranty does not apply to any part of a prod
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix A Revision 1 A–44 Notes:
B-1 Appendix B. CABLE DRAWINGS B.1 Overview This appendix provides line details for the cables available for use with the SPOD C-, X-, or Ku-Band Ou
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix B Revision 1 B-2 B.2 Control and Data Cables App B FIG CEFD CABLE P/N DESCRIPTION US
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix B Revision 1 B-3 B.2.1 Serial Interface Cable The Comtech EF Data CLC-10 Serial M&am
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix B Revision 1 B-4 B.2.2 Ethernet Interface Cable The Comtech EF Data Ethernet Utility
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix B Revision 1 B-5 B.2.3 19-Pin COMMS Cable (100’) This cable connects between your des
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix B Revision 1 B-6 B.2.4 19-Pin COMMS Cable (250’) This cable connects between your des
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix B Revision 1 B-7 B.2.5 Redundant Loop Cable – Tx Only Use the CA-0020655 Redundant Lo
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix B Revision 1 B-8 B.3 RF Cables App B FIG CEFD CABLE P/N DESCRIPTION USED FOR: REF A
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix B Revision 1 B-9 B.3.1 RF Cable (Type ‘N’) Use this Type ‘N’ cable for the Rx or Tx c
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Preface Revision 1 xvi Notes:
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Appendix B Revision 1 B-10 Notes:
C–1 SPOD PS 1 SPOD PS 1.5 SPOD PS 2 Appendix C. MAINTENANCE C.1 Overview Figure C-1. Comtech EF Data SPOD Outdoor
SPOD C-, X-, or Ku-Band Outdoor Amplifiers MN-SPODPSX Appendix C Revision 1 C–2 Figure C-2. SPOD Web Server Interface ‘Status |Trending Graphs’ Pag
SPOD C-, X-, or Ku-Band Outdoor Amplifiers MN-SPODPSX Appendix C Revision 1 C–3 Figure C-3. SPOD PS 1 Shroud Screw Locations Figure C-4. Remove th
SPOD C-, X-, or Ku-Band Outdoor Amplifiers MN-SPODPSX Appendix C Revision 1 C–4 Figure C-5. Disconnect the Fan Power Supply Figure C-6. SPOD PS 1
SPOD C-, X-, or Ku-Band Outdoor Amplifiers MN-SPODPSX Appendix C Revision 1 C–5 C.3 Clean the SPOD PS 1.5 Heat Sinks To clean the SPOD PS 1.5 Heat
SPOD C-, X-, or Ku-Band Outdoor Amplifiers MN-SPODPSX Appendix C Revision 1 C–6 Figure C-8. SPOD PS 1.5 Shroud Screw Locations
SPOD C-, X-, or Ku-Band Outdoor Amplifiers MN-SPODPSX Appendix C Revision 1 C–7 Figure C-9. Remove the Fan Shroud Figure C-10. Disconnect the Fa
SPOD C-, X-, or Ku-Band Outdoor Amplifiers MN-SPODPSX Appendix C Revision 1 C–8 Figure C-11. SPOD PS 1.5 Heat Sink Location Figure C-12. Reconne
SPOD C-, X-, or Ku-Band Outdoor Amplifiers MN-SPODPSX Appendix C Revision 1 C–9 C.4 Clean the SPOD PS 2 Heat Sinks To clean the SPOD PS 2 Heat Sink
1–1 SPOD PS 1 SPOD PS 1.5 SPOD PS 2 Chapter 1. INTRODUCTION 1.1 Overview Comtech EF Data’s SPOD family of C-, X-, and Ku-Band Ou
SPOD C-, X-, or Ku-Band Outdoor Amplifiers MN-SPODPSX Appendix C Revision 1 C–10 Figure C-13. SPOD PS 2 Shroud Screw Locations Figure C-14. Re
SPOD C-, X-, or Ku-Band Outdoor Amplifiers MN-SPODPSX Appendix C Revision 1 C–11 Figure C-15. Disconnect the Fan Power Supplies Figure C-16. SPO
SPOD C-, X-, or Ku-Band Outdoor Amplifiers MN-SPODPSX Appendix C Revision 1 C–12 Figure C-17. Reconnect the Fan Power Supplies
2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 • 333 • 2200 PHONE 480 • 333 • 2161 FAX
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Introduction Revision 1 1–2 1.3 Features 1.3.1 The Solid-State Advantage The SPOD is construc
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Introduction Revision 1 1–3 1.4 Summary of Specifications 1.4.1 Characteristics Band Model
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Introduction Revision 1 1–4 Parameter Specification Gain Min (Typical) All Power Levels 70 (
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Introduction Revision 1 1–5 1.4.2 Environmental Parameter Specification Temperature Operating
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Introduction Revision 1 1–6 1.5 Dimensional Envelopes Note the following: 1) Typical for all
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Introduction Revision 1 1–7 1.5.1 SPOD PS 1 Dimensional Envelopes Figure 1-2. SPOD PS 1 C-Ba
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Introduction Revision 1 1–8 Figure 1-3. SPOD PS 1 X-Band Dimensional Envelope
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Introduction Revision 1 1–9 Figure 1-4. SPOD PS 1 Ku-Band Dimensional Envelope
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Introduction Revision 1 1–10 1.5.2 SPOD PS 1.5 Dimensional Envelopes Figure 1-5. SPOD PS 1.5
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Introduction Revision 1 1–11 Figure 1-6. SPOD PS 1.5 X-Band Dimensional Envelope
Copyright © 2014 Comtech EF Data. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.22
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Introduction Revision 1 1–12 Figure 1-7. SPOD PS 1.5 Ku-Band Dimensional Envelope
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Introduction Revision 1 1–13 1.5.3 SPOD PS 2 Dimensional Envelopes Figure 1-8. SPOD PS 2 C-
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Introduction Revision 1 1–14 Figure 1-9. SPOD PS 2 X-Band Dimensional Envelope
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Introduction Revision 1 1–15 Figure 1-10. SPOD PS 2 Ku-Band Dimensional Envelope
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Introduction Revision 1 1–16 Notes:
2–1 Chapter 2. SYSTEM CONNECTIONS, INSTALLATION AND STARTUP 2.1 Cabling Connection Types 2.1.1 Coaxial Cable Connections Coupling Type Connector Typ
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX System Connections, Installation and Startup Revision 1 2–2 2.1.2 Circular Cable Connections
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX System Connections, Installation and Startup Revision 1 2–3 Figure 2-3. SPOD PS 1 Connections
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX System Connections, Installation and Startup Revision 1 2–4 PS 1/PS 1.5 PS 2 2.
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX System Connections, Installation and Startup Revision 1 2–5 2.3.3 Connector ‘J3 | POWER IN’ (
ii BLANK PAGE
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX System Connections, Installation and Startup Revision 1 2–6 2.3.4 Connector ‘J3 | POWER IN’ (
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX System Connections, Installation and Startup Revision 1 2–7 2.3.4.3 SPOD PS 2 ‘J3 | POWER IN’
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX System Connections, Installation and Startup Revision 1 2–8 PS 1/PS 1.5
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX System Connections, Installation and Startup Revision 1 2–9 2.3.6 Connector ‘J9 | OUTPUT SAMP
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX System Connections, Installation and Startup Revision 1 2–10 2.4 SPOD Standalone Installation
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX System Connections, Installation and Startup Revision 1 2–11 This kit accommodates a pole d
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX System Connections, Installation and Startup Revision 1 2–12 KT-0000095 PS 1/PS 1.5 Single Un
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX System Connections, Installation and Startup Revision 1 2–13 KT-0000125 SPOD PS 2 Single Uni
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX System Connections, Installation and Startup Revision 1 2–14 KT-0020524 PS 2 Single Unit She
3–1 Chapter 3. UPDATING FIRMWARE 3.1 Overview TO ENSURE OPTIMAL PERFORMANCE, IT IS IMPORTANT TO OPERATE THE SPOD WITH ITS LATEST AVAILABLE FIRMWARE
iii TABLE OF CONTENTS TABLE OF CONTENTS ...I
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Updating Firmware Revision 1 3–2 3.2 Getting Started: Prepare for the Firmware Download 1) Fi
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Updating Firmware Revision 1 3–3 o Your Ethernet connection may use either the CAT5 Ethernet a
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Updating Firmware Revision 1 3–4 D. Obtain the firmware information via one of the following m
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Updating Firmware Revision 1 3–5 B. Use Windows Explorer to create and rename the temporary
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Updating Firmware Revision 1 3–6 • Next, open a Command-line window… o For Windows 95 or Win
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Updating Firmware Revision 1 3–7 3.3 Download and Extract the Firmware Update 1) First, downl
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Updating Firmware Revision 1 3–8 o Click [Save] to open the ‘Save As’ window. Be sure to selec
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Updating Firmware Revision 1 3–9 The firmware files have been successfully downloaded and are n
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Updating Firmware Revision 1 3–10 2) Use Command-line to transfer (FTP) the files from the Use
4–1 Chapter 4. ETHERNET-BASED REMOTE PRODUCT MANAGEMENT 4.1 Introduction Ethernet-based remote management and control of the SPOD is available when t
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Table of Contents Revision 1 iv 1.4.2 Environmental ...
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–2 4.2 Ethernet Management Interface Pro
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–3 MIB File/Name (where ‘x’ is revision l
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–4 The SPOD supports the following Faults
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–5 ODUPowerSupply13VStatus 1.3.6.1.4.1.6
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–6 4.4 Telnet Interface The SPOD provide
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–7 Configure HyperTerminal as follows: 1
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–8 4.5 Web Server (HTTP) Interface A use
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–9 You must assign a unique IP Address f
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–10 4.5.3 Web Server Interface – Operati
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–11 4.5.3.4 Action Buttons Action button
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Table of Contents Revision 1 v 4.2 Ethernet Management Interface Protocols ...
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–12 4.5.4 Web Server Interface – Web Pag
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–13 4.5.4.1.2 Home | Contact Use this pa
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–14 4.5.4.1.3 Home | Support For this p
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–15 4.5.4.2 Admin Pages The Admin pages
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–16 System Account Access Information •
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–17 4.5.4.2.2 Admin | SNMP Sect. 4.3 SN
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–18 Click [Submit SNMP] to save any chang
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–19 Serial • Remote Address – Enter a va
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–20 4.5.4.3.2 Config | Utility Use this
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–21 Circuit ID Enter a Circuit ID (unit i
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Table of Contents Revision 1 vi 5.2.3 Mute Control ...
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–22 4.5.4.3.3 Config | Redundancy Appen
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–23 4.5.4.4 Status Pages Use these pages
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–24 • An operating parameter is changed,
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–25 4.5.4.4.3 Status | FETs Use this rea
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–26 4.5.4.4.4 Status | Events Use this p
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–27 Alarm Mask Use the drop-down lists to
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–28 4.5.4.4.5 Status | Statistics Use th
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–29 Statistics Configuration The Statist
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–30 4.5.4.4.6 Status | Trending Graphs
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–31 The LNB CURRENT and RX MUTE STATUS g
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Table of Contents Revision 1 vii B.2.2 Ethernet Interface Cable...
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–32 Temperature Graph As noted by the g
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–33 LNB Current Graph This graph display
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Ethernet-based Remote Product Management Revision 1 4–34 This graph displays the mute status (
5–1 Chapter 5. SERIAL-BASED REMOTE PRODUCT MANAGEMENT 5.1 Overview Serial-based remote product management of Comtech EF Data’s SPOD family of Outdoor
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–2 5.2.2 Attenuator Control The SPOD gain c
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–3 • Thermal Shutdown – A temperature fault
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–4 • RAS – Retrieve Alarm Status. Displays
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–5 5.3 Remote Control Protocol and Structur
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–6 5.3.2 EIA-232 This is a much simpler con
SPOD C-, X-, or Ku-Band Outdoor Amplifier MN-SPODPSX Serial-based Remote Product Management Revision 1 5–7 Target-to-Controller Start of Packet Tar
Commentaires sur ces manuels