1.8.3.5 Altitude
Table 1-8 Altitude
Non-Operating Requirements
Altitude Ranges
Low Limits -50 ft (-15.2 m) -50 ft (-15.2 m)
High Limits 10,000 ft (3048 m) 35,000 ft (10,668 m)
1.8.3.6 Airborne Contaminants
Table 1-9 Airborne Contaminants
Non-Operating Requirements
Airborne contaminants ISA-71 Level G1 – Maximum corrosive contaminant levels measured at ≤ 50% relative
humidity. See Table 3 in ISA-71.04-1985.